Troubleshooting Chart - Kobalt 143075 Manual Del Operador

Ocultar thumbs Ver también para 143075:
Tabla de contenido

Publicidad

I _E,_,,_,
TROUBLESHOOTING
CHART
I
Note: Troubleshooting
problems may have similar causes and solutions,
PROBLEM
POSSIBLE CAUSE
SOLUTION
Low pressure or not
Tank petcock is open
Close petcock
enough air
Fittings Leak
Check fittings with soapy water. Tighten or reseal leaking fittings.
or
DO NOT OVERTIGHTEN.
Compressor
does not
Restricted air intake
Clean or replace intake filter element.
stop
Prolonged excessive use of air
Decrease amount of air used.
Compressor
not large enough
Check air requirement of accessory. If it is higher than CFM and
pressure supplied by compressor, you need a larger compressor.
Most accessories are rated at 25% of actual CFM while running
continuously.
Hole in air hose
Check and replace if necessary.
Tank leaks
_Ik _lmmediately
replace unit. DO NOT attempt to
repair.
Blown seals
Replace seals.
Valve leaks
Replace valve.
Leaking or worn piston
Replace piston.
Air leaks from regulator,
Dirty or damaged regulator
Replace regulator or internal parts.
or regulator
does not
internal parts.
regulate pressure
Regulated pressure
This is normal
If pressure drops too low, adjust regulator while accessory is used.
gauge reading drops
Compressor
not large enough
Check air requirement of accessory. If it is higher than CFM and
when air accessory
is
pressure supplied by compressor, you need a larger compressor.
being used
Most accessories are rated at 25% of actual CFM while running
continuously.
Pressure
relief valve
Tank pressure exceeded normal
Replace pressure switch
opens
operating pressure
Pressure switch stuck
Motor will not run
Tank pressure exceeds preset
pressure switch limit
Motor overload protection has
tripped
Fuse blown or circuit breaker
tripped
Replace pressure switch
Motor will start automatically when tank pressure drops below
kick-in pressure of pressure tank.
Let motor cool off and overload switch will automatically reset. This
may take several minutes.
• Replace blown fuse or reset circuit breaker. Do not use fuse or
circuit breaker with higher rating than specified for your branch
circuit.
• Check for proper fuse; "Fusetron" type T is acceptable.
• Check for low voltage and proper extension cord size.
• Disconnect other applications from circuit. Operate compressor
on a dedicated circuit.
Check valve stuck open
Remove and clean or replace.
Wrong wire gauge in cord or
Check for proper gauge and extension cord length.
excessive extension cord length
Loose electrical connections
Contact authorized service center.
Paint spray on internal motor
Have checked at service center. Do not operate compressor in the
parts
paint spray area
Possible defective motor
Have checked at service center.
200-2673
15

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

236005

Tabla de contenido