Description and Mounting Instructions
LED Driver with constant output current for the operation of LED
(Electronic power supply unit)
MODEL: 464200, 464201, 464202
1. Technical Data:
Rated voltage
Shared load operation
Constant output current
Secondary voltage
Protection Class
Open-circuit safety
Short circuit and overload protection
Ambient temperature ta
Casing temperature tc-point
Standards
EMC conformity
Diameter of wires
Cable
(Terminals)
Bared wire end
2. Installation Instructions
The installation may only be carried out by an electrical specialist in accordance with international and
national standards.
When working on electrical systems, protection against electric shock is to be ensured by disconnecting the
system. Install primary and secondary mains intersection-free (RFI protection).
Before switching on the supply voltage all LED must be completely wired and connected!
The LED Driver is strictly suited for the use with LED that requires a constant current of 700mA.
When connecting the LED, careful attention should be paid to connecting + and - to the right terminals on the LED
Driver.
LED Drivers mounted outside of luminaires are to be screwed tightly to the respective surface by their screw holes and
careful attention is to be paid to the connecting cables and the lamp cables being fastened securely in the strain relief.
The tc temperature may not be exceeded for any kind of mounting. The devices do not contain any serviceable
components and may not be opened.
3. Important Information
Our LED Drivers are surge-voltage-stable with values far above those prescribed by the respective standards. As a
protection against high voltage surges, as they occur e.g. when switching fluorescent lamps and discharge lamps with
an inductive ballast, motors (fans, etc.) and other inductive charges, the load circuits for devices of this kind are to be
clearly separated from each other.
The LED Driver cannot be regulated via a phase cut-on or cut-off dimmer!
4. Safety Functions
In case of a short circuit or overload the LED Driver will automatically cut off. It does not have a fuse of the conventional
kind. Thus the load circuit is not separated!
As soon as the defect has been repaired, the LED Driver will automatically cut back in.
5. Excess Temperature
In case of excess temperature through external heat sources or impermissible covers the built-in over temperature
control will reduce power. As soon as the LED Driver has cooled off, it will automatically cut back in.
6. Heat Dissipation and Heat Transfer
Operation in excess ambient temperature or through external heating will reduce the service life. During the installation
process (particularly into luminaires), heat dissipation (heat transfer) is to be provided through suitable measures. The
ambient temperature and/or tc temperature may not be exceeded at any time. We are not liable for damage resulting
from improper use.
Order-No. 464200, 464201, 464202
© SLV Elektronik GmbH, Daimlerstr. 21-23, 52531 Übach-Palenberg,
Germany, Tel. +49 (0)2451 4833-0
CE
464200
LSVC3B-Z UNI
3W
4-5VDC SELV
II
Electronic disconnection with automatic restart
max. 70° C
EN 61547, EN 55015, EN 61000-3-2, EN 61000-3-3
PRI
0,75 – 1,5mm²
AWG 20-16
SEC
PRI
6mm
SEC
02/2011
464202
LLVC12B UNI
100-240V~ 50-60Hz
6-12W
700mA
8-18VDC SELV
guaranteed
-20° C - +50° C
max. 75° C
EN 61347, EN 62384
0,5 – 1,5mm²
AWG 20-16
0,75 – 1,5mm²
AWG 22-14
9mm
6mm
464201
LTVC18B-Z UNI
10-18W
12-27VDC SELV
I
max . 70° C
0,5 – 1,5mm²
AWG 20-16
9mm