Descargar Imprimir esta página

Grohe Bridgeford 33 870 Instrucciones De Montaje página 5

Ocultar thumbs Ver también para Bridgeford 33 870:

Publicidad

Application
Operation is possible in conjunction with:
• Pressurized storage heaters
Operation is not possible with:
• Low-pressure storage heaters (displacement water heaters)
Specification
• Max. flow
GROHE EcoJoy
• Flow pressure
- min.
- recommended
- greater than 72.5 psi, fit pressure reducing valve
• Max. operating pressure
• Test pressure
• Temperature
- max. (hot water inlet)
• Water connection:
• Deck thickness max.
• Non reversible cartridge
Notes:
- Major pressure differences between cold and hot water supply
should be avoided.
- To be installed according to local codes and regulations.
- This faucet is not intended for the use with portable appliances.
Installation
Flush piping system prior and after installation of faucet
thoroughly!
Prepare sink faucet
Refer to the dimensional drawing on page 1.
Mount sink faucet, see fig. [1].
1. Push escutcheon (A) on faucet.
2. Fit O-Ring (A1) and insert faucet into sink. Feed the connection
hoses separately through the sink.
3. Push on ring (B) and insert tube (C).
4. Fit brace (D), if necessary, with washer (E) and connect nut (F)
with tube (C). To do this, insert fitting key (G) into tube (C) and
turn fitting key (G) clockwise to fasten faucet.
(Tube may also have to be turned with an 22mm open ended
wrench.)
Note:
If brace (D) is omitted, deck thickness can be increased by 9/16"
to a total of 2 3/8".
The following lever positions can also be obtained, see fig. [2].
Connect sink faucet, see figs. [1] and [3].
- Cold water connection
- Hot water connection
Avoid cross connection. The cartridge is not reversible.
Connect spray hose (H) and rinse spray (K), see figs. [4] and [5].
1. Feed the spray hose (H) through the spout (J), see fig. [4].
2. Feed the spray hose (H) through the faucet body from above and
fit spout (J) so that it snaps into place, see fig. [5].
3. Connect the rinse spray (K) without using any additional seals to
the spray hose (H).
4. With rinse spray inserted slide on spring (L) onto spray hose (H)
from below.
5. Install the snap coupling (M) on the end of the spray hose (H)
and tighten by hand.
6. Pull the sleeve (M1) of the snap coupling (M) downwards and fit
to the union (N).
To ensure that the rinse spray (K) is correctly seated when
inserted, lug (J1) on the spout must engage in recess on the rinse
spray (K1).
English
8.3 L/min or 2.2 gpm/60 psi
5.7 L/min or 1.5 gpm/60 psi
7.25 psi
14.5 - 72.5 psi
145 psi
232 psi
176 °F
cold - RH
hot - LH
2 3/8"
= right
= left
Open cold and hot water supply and check connections for
leakage.
Operation
1. Lever head (Lever head position right)
Slide lever to right
Slide lever to left
Slide lever towards front
Slide lever towards back
2. Rinse spray
Open faucet. Water will always emerge first from the aerator.
Diverter button:
Switching to spray flow by pushing and holding the diverter
button (K2), see fig. [5].
Setting free the diverter button causes the water flow to aerator.
Flow rate limiter
This faucet is fitted with a flow rate limiter, permitting an infinitely
variable individual reduction of the flow rate. The highest possible
flow rate is set by the plant before despatch.
The use of flow rate limiters in combination with hydraulic
instantaneous water heaters is not recommended.
To activate see "Replacing the cartridge" point 1 to 4, figs. [6]
and [7].
Maintenance
Inspect and clean all parts, replace as necessary and grease with
special grease.
Shut off cold and hot water supply!
I. Replacing the cartridge, see fig. [6].
1. Detach cover cap (O) and screw out screw (P).
2. Pull off lever (Q).
3. Remove fixing screw (R) and pull off adaptor (S).
4. Turn cap (T) through 180° (slot pointing upwards) and pull off the
cap.
5. Remove screws (U) and detach complete cartridge (V).
6. Change the complete cartridge (V).
Assemble in reverse order.
Observe the correct installation position!
Make sure that the cartridge seals engage in the grooves on the
housing. Fit screws (U) and tighten evenly and alternately.
II. Strainer and spray, see figs. [8] and [9].
1. Unscrew rinse spray (K) and remove non-return valve (W).
2. Unscrew spray (X) with fitting key (G), see fig. [8].
3. Clean strainer (Y) and spray (X).
4. With SpeedClean nozzles simply rub fingers over spray to
remove limescale, see fig. [9].
We guarantee that the SpeedClean nozzles will function
unchanged for a period of five years.
Assemble in reverse order.
Replacement parts, see page 2 ( * = special accessories).
Care
Instructions for care of this faucet will be found in the Limited
Warranty supplement.
= open (water flow)
= closed
= cold water
= hot water
4

Publicidad

loading