Access To The Fans; Door Closing Pressure; Maintenance Of The Chimney - FRANCO BELGE Boutiques de Feu Ubinas Instrucciones De Montaje

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

"Ubinas" - ref. 634 10 47/634 10 48
3
1
1
- 4 screws
2
- Ash pan.
3
- Door.
Figure 16 - Access to the fans
3
2
- Screws
- Pressure
1
2
screw
Figure 17 - Door closing pressure
11
4
5
5
1
2
4
- Front plate
5
- grids
1
1
- Screw
3

2.16. Access to the fans

Figure 16 (634 10 47 only)
Open the main door (3) and to withdraw the ashtray (2),
to remove the 4 screws (1) and to deposit the grids
right-hand side and left (5).
To go up them, proceed in the opposite order.

2.17. Door closing pressure

Figure 17
The closing latch pivots on a screw locked by a
pressure screw.
Remove the window by removing the 2 screws (1).
Loosen pressure screw (2).
Tighten or loosen the screw (3) according to the
pressure required.
Retighten the pressure screw (2) and raise the window.

2.18. Maintenance of the Chimney

Very important : In order to avoid any incident
(chimney fire, etc...), maintenance tasks must be
carried out regularly. If the appliance is regularly used,
the chimney should be swept several times per year,
together with the stovepipe connection section.
If the chimney catches fire, you must cut off the flue
draught, close the doors and windows, hatches and
keys and call the Fire Brigade without delay.
DO NOT OPEN THE DOOR OF THE APPLIANCE
(OR AIR INLET)
UNDER ANY CIRCUMSTANCES.
Installation instructions
Technical manual "646"

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

634 10 47634 10 48

Tabla de contenido