  • Página 1 Installation and Operation Manual X-VA-1110-1140-eng Part Number: 541B040AAG ® Brooks 1110 and 1140 Series September, 2012 ® Glass Tube Full-View Flowmeters Model 1110 Model 1140 Full-View Flowmeter Full-View Flowmeter (NPT Connections) (Flange Connections)
  • Página 2 Installation and Operation Manual X-VA-1110-1140-eng Part Number: 541B040AAG ® Brooks 1110 and 1140 Series September, 2012...
  • Página 3 Installation and Operation Manual X-VA-1110-1140-eng Part Number: 541B040AAG ® Brooks 1110 and 1140 Series September, 2012 WARNING WARNING GLASS TUBE EXPLOSION HAZARD Protective sleeve must remain over glass tube. GLASS TUBE (Meter sizes 7 - 13 only) EXPLOSION Fasten meter windows securely. HAZARD Failure to comply could result in serious personal injury or property damage.
  • Página 4 We appreciate this opportunity to service your flow measurement and control requirements with a Brooks Instrument device. Every day, flow customers all over the world turn to Brooks Instrument for solutions to their gas and liquid low-flow applications. Brooks provides an array of flow measurement and control products for various industries from biopharmaceuticals, oil and gas, fuel cell research and chemicals, to medical devices, analytical instrumentation, semiconductor manufacturing, and more.
  • Página 5: Tabla De Contenido

    Contents Installation and Operation Manual X-VA-1110-1140-eng Part Number: 541B040AAG ® Brooks 1110 and 1140 Series September, 2012 Paragraph Page Number Number Section 1 Introduction 1-1 Description ............................1-1 1-2 Design Features ..........................1-1 1-3 Specifications ............................. 1-1 1-4 Optional Equipment (Mountings, Valves and Flow Controllers) ............1-7 Section 2 Installation 2-1 General ..............................
  • Página 6 Contents Installation and Operation Manual X-VA-1110-1140-eng Part Number: 541B040AAG ® Brooks 1110 and 1140 Series September, 2012 Figures Figure Page Number Number 1-1 Dimensions 127mm & 250mm Full-View Flowmeters ................ 1-6 1-3 Float Types ............................1-7 2-1 Typical Bypass Installation ......................... 2-3 3-1 Typical Bypass Installation .........................
  • Página 7: Section 1 Introduction

    Section 1 Introduction Installation and Operation Manual X-VA-1110-1140-eng Part Number: 541B040AAG ® Brooks 1110 and 1140 Series September, 2012 1-1 Description ® ® The Brooks Full-View glass tube meters are designed to offer a wide variety of meter configurations to meet a broad range of metering applications.
  • Página 8 Section 1 Introduction Installation and Operation Manual X-VA-1110-1140-eng Part Number: 541B040AAG Brooks ® 1110 and 1140 Series September, 2012 Pressure Ratings Refer to Table 1-1 for maximum non-shock pressure for rib guided and plain tapered tubes. Note: CRN meters have a lower pressure rating. Pressure Equipment Directive (PED) 97/23/EC See Table 1-1.
  • Página 9 Section 1 Introduction Installation and Operation Manual X-VA-1110-1140-eng Part Number: 541B040AAG ® Brooks 1110 and 1140 Series September, 2012 WARNING GLASS TUBE EXPLOSION HAZARD Plastic protective sleeve must remain over glass tube. (Meter sizes 7 -13 only) Fasten meter windows securely. Do not operate above pressure and temperature limits.
  • Página 10 Section 1 Introduction Installation and Operation Manual X-VA-1110-1140-eng Part Number: 541B040AAG Brooks ® 1110 and 1140 Series September, 2012 Housing and Window Bezel Standard: Aluminum with polyurethane paint. Optional: 18-8 stainless steel. End Fittings 316 stainless steel,steel, Hastelloy C, CPVC Sizes 2-8, PVC Sizes 9-10, brass.
  • Página 11 Section 1 Introduction Installation and Operation Manual X-VA-1110-1140-eng Part Number: 541B040AAG ® Brooks 1110 and 1140 Series September, 2012 Table 1-2 Connections Model 1110 Model 1114 Model 1140 Model 1144 Meter Inlet&Outlet Inlet&Outlet Inlet&Outlet Inlet&Outlet Size Horizontal Vertical Horizontal Vertical (NPT) (NPT) (Flange)
  • Página 12 Section 1 Introduction Installation and Operation Manual X-VA-1110-1140-eng Part Number: 541B040AAG Brooks ® 1110 and 1140 Series September, 2012 All Dimensions in Inches 1110 - 1140 1114 1144 Nominal Nominal Meter Scale Length Scale Length Nominal Scale Length (MM) Meters Meters (MM) (MM)
  • Página 13: Optional Equipment (Mountings, Valves And Flow Controllers)

    Section 1 Introduction Installation and Operation Manual X-VA-1110-1140-eng Part Number: 541B040AAG ® Brooks 1110 and 1140 Series September, 2012 1-4 Optional Equipment ( Mountings, Valves and Flow Controllers) • Mountings: Brackets for panel mounting flush or front of panel • Valves: Available for connection sizes 1/4” through 1” only. Horizontal stem in outlet or inlet and fitting Sizes 2 through 10.
  • Página 14 Section 1 Introduction Installation and Operation Manual X-VA-1110-1140-eng Part Number: 541B040AAG Brooks ® 1110 and 1140 Series September, 2012 Table 1-3 Capacities, Table 1-4 Capacities, 150mm Scale, Rib Guided Tube, Spherical Float 250mm Scale, Rib Guided Tube, Spherical Float Maximum Flow Rate MAXIMUM FLOW RATE Meter Water...
  • Página 15 Section 1 Introduction Installation and Operation Manual X-VA-1110-1140-eng Part Number: 541B040AAG ® Brooks 1110 and 1140 Series September, 2012 Table 1-5 Capacities, 250mm Scale , Rib Guided Tubes, Standard Float Water Air @ 14.7 psia and 70°F (21°C) Pressure Viscosity Pressure Meter Drop...
  • Página 16 Section 1 Introduction Installation and Operation Manual X-VA-1110-1140-eng Part Number: 541B040AAG Brooks ® 1110 and 1140 Series September, 2012 Table 1-6 Capacities, 127mm Scale, Rib Guided Tubes, Standard Float Water Air @ 14.7 psia and 70°F (21°C) Pressure Viscosity Pressure Meter Drop Immunity...
  • Página 17: Section 2 Installation

    If the packing case is damaged, the local carrier should be notified at once regarding his liability. A report should be submitted to your nearest Product Service Department. Brooks Instrument 407 W. Vine Street P.O. Box 903...
  • Página 18: Return Shipment

    E-mail: BrooksEu@BrooksInstrument.com All flow instruments returned to Brooks requires completion of Form RPR003-1, Brooks Instrument Decontamination Statement, along with a Material Safety Data Sheet (MSDS) for the fluid(s) used in the instrument. Failure to provide this information will delay processing by Brooks personnel.
  • Página 19: Installation Of Meter

    Section 2 Installation Installation and Operation Manual X-VA-1110-1140-eng Part Number: 541B040AAG ® Brooks 1110 and 1140 Series September, 2012 2-7 Installation of meter A. Location For proper operation of the Full-View flowmeter it must be mounted within 6 degrees of true vertical, with the inlet connection at the bottom of the meter, and the outlet at the top.
  • Página 20 Section 2 Installation Installation and Operation Manual X-VA-1110-1140-eng Part Number: 541B040AAG ® Brooks 1110 and 1140 Series September, 2012 THIS PAGE WAS INTENTIONALLY LEFT BLANK...
  • Página 21: Section 3 Operation

    Installation and Operation Manual Section 3 Operation X-VA-1110-1140-eng Part Number: 541B040AAG ® Brooks 1110 and 1140 Series September, 2012 3-1 General After the flowmeter has been properly installed in the process, it is ready for operation. When initiating flow, slowly open the valve to avoid a flow surge.Bypass is a help in bringing the flow on smoothly.
  • Página 22 Installation and Operation Manual Section 3 Operation X-VA-1110-1140-eng Part Number: 541B040AAG ® Brooks 1110 and 1140 Series September, 2012 WARNING GLASS TUBE EXPLOSION HAZARD Protective sleeve must remain over glass tube. (Meter sizes 7 - 13 only) Fasten meter windows securely. Failure to comply could result in serious personal injury or property damage.
  • Página 23: Section 4 Maintenance And Cleaning

    Section 4 Maintenance and Cleaning Installation and Operation Manual X-VA-1110-1140-eng Part Number: 541B040AAG ® Brooks 1110 and 1140 Series September, 2012 4-1 General This section provides the assembly and disassembly procedures for the Brooks Full-View flowmeters.
  • Página 24: Disassembly And Reassembly

    Section 4 Maintenance and Cleaning Installation and Operation Manual X-VA-1110-1140-eng Part Number: 541B040AAG ® Brooks 1110 and 1140 Series September, 2012 4-2 Disassembly and Reassembly Note: Step number preceded by an asterisk (*) apply only to rod guided floats. A. Disassembly 1.
  • Página 25 Section 4 Maintenance and Cleaning Installation and Operation Manual X-VA-1110-1140-eng Part Number: 541B040AAG ® Brooks 1110 and 1140 Series September, 2012 4. Install the gland followers, polycarbonate sleeve, Size 7 (1/2") and larger, gland rings, and packing on the tube. Note: Both hat gaskets are purposely tight fitting and can be installed more easily from the inlet (narrower) end of the tube.
  • Página 26 Section 4 Maintenance and Cleaning Installation and Operation Manual X-VA-1110-1140-eng Part Number: 541B040AAG ® Brooks 1110 and 1140 Series September, 2012 THIS PAGE WAS INTENTIONALLY LEFT BLANK...
  • Página 27 Section 5 Accessories Installation and Operation Manual X-VA-1110-1140-eng Part Number: 541B040AAG ® Brooks 1110 and 1140 Series September, 2012 5-1 General See Optional Equipment, Section 1-4, for specifications, dimensions, and options. Refer to both parts of Figures 5-1a thru 5-1c and Table 5-1 for exploded drawing and parts.
  • Página 28 Section 5 Accessories Installation and Operation Manual X-VA-1110-1140-eng Part Number: 541B040AAG ® Brooks 1110 and 1140 Series September, 2012 Figure 5-1a Model 1110 Exploded Parts Drawing...
  • Página 29 Section 5 Accessories Installation and Operation Manual X-VA-1110-1140-eng Part Number: 541B040AAG ® Brooks 1110 and 1140 Series September, 2012 Figure 5-1b Model 1110 Exploded Parts Drawing (Continued)
  • Página 30 Section 5 Accessories Installation and Operation Manual X-VA-1110-1140-eng Part Number: 541B040AAG ® Brooks 1110 and 1140 Series September, 2012 Figure 5-1c Model 1110 Exploded Parts Drawing (Continued)
  • Página 31 Section A - Essential Instructions Installation and Operation Manual X-VA-1110-1140-eng Part Number:541B040AAG Brooks ® 1110 and 1140 Series September, 2012 Bulgarian Brooks Instrument Brooks Instrument. Brooks Instrument : (1) . (2) Brooks Instrument (PED) 0,5 bar (g) 25 mm 1" ( (PED).
  • Página 32 P ed instalací si p e t te následující instrukce! Spole nost Brooks Instrument konstruuje, vyrábí a testuje tento produkt tak, aby splnil mnoho národních a mezinárodních standard . P ístroje musí být ádn nainstalovány, používány a udržovány tak, aby byl zajišt n jejich nep etržitý provoz v rámci normálních technických specifikací. Musíte dodržovat následující...
  • Página 33 Section A - Essential Instructions Installation and Operation Manual X-VA-1110-1140-eng Part Number:541B040AAG Brooks ® 1110 and 1140 Series September, 2012 Dansk Grundlæggende vejledninger Læs disse før anvendelse! Brooks Instruments designer, fremstiller og afprøver sine produkter således, at de tilpasser sig både de indenrigs og internationale standarder. Disse udstyr bør installeres, bruges og repareres omhyggeligt, så...
  • Página 34 Lees ze voordat u verder gaat! Brooks Instrument ontwerpt, produceert en test haar producten zodanig dat ze voldoen aan vele nationale en internationale normen. Deze producten moeten correct worden geïnstalleerd, bediend en onderhouden zodat ze binnen hun normale specificaties blijven werken. De volgende instructies moeten worden toegevoegd aan en geïntegreerd in uw veiligheidsprogramma als u producten van Brooks Instrument installeert, bedient en onderhoudt.
  • Página 35 Olulised juhised Enne kasutamist lugege hoolikalt läbi! Brooks Instrument konstrueerib, valmistab ja katsetab oma tooteid selliselt, et need vastaksid paljude erinevate riiklike ja rahvusvaheliste standardite nõuetele. Ainult nõuetekohane paigaldamine, kasutamine ja hooldamine tagab toodete katkematu talitluse tavaspetsifikatsiooni raames. Brooks Instrument'i toodete paigaldamisel, kasutamisel ja hooldamisel tuleb täita alljärgnevaid juhiseid ja integreerida need asjakohasesse ohutusprogrammi.
  • Página 36 Perusohjeet Lue ensin ohjeet huolellisesti! Brooks Instrument suunnittelee, valmistaa ja testaa laitteensa vastaamaan useimpien kotimaisten ja kansainvälisten standardien vaatimuksia. Tuotteet tulee asentaa, käyttää ja huoltaa käyttöohjeiden mukaan jotta niiden toimivuus taataan. Brooks Instrumentin laitteiden asennuksessa, käytössä ja huollossa on noudatettava soveltuvia määräyksiä ja ohjeita, lisäksi mainitut ohjeet on huomioitava työsuojelun ohjeistuksessa.
  • Página 37 Brooks Instrument et que des personnes qualifiées effectuent le remplacement. Les pièces et procédures non autorisées peuvent porter atteinte au fonctionnement du produit et mettre en péril la sécurité de votre procédé. Les remplacements par des pièces d’apparence similaire peuvent entraîner des incendies, des risques électriques ou un mauvais fonctionnement.
  • Página 38 Bitte zuerst lesen! Brooks Instrument entwickelt, produziert und testet seine Produkte derart, dass sie viele nationale und internationale Standards erfüllen. Nur bei korrektem Einbau sowie richtiger Bedienung und Wartung dieser Produkte ist ein Betrieb unter Einhaltung der Standardvorgaben sichergestellt. Die folgenden Anweisungen müssen eingehalten werden und in Ihr Sicherheitsprogramm integriert werden, wenn Sie Brooks Produkte installieren, bedienen und warten.
  • Página 39 Section A - Essential Instructions Installation and Operation Manual X-VA-1110-1140-eng Part Number:541B040AAG Brooks ® 1110 and 1140 Series September, 2012 Greek Brooks Instrument Brooks Instrument. ’ Brooks Instrument. : (1) . (2) Brooks Instrument. (PED) 0,5 bar (g) 25 mm (PED).
  • Página 40 üzemeltetni és karbantartani ahhoz, hogy mindenképpen a normál m ködési tartományuknak megfelel en üzemelhessenek. Az alábbi utasításokat be kell tartani, és be kell építeni a munkavédelmi programba a Brooks Instrument termékeinek telepítése, üzemeltetése és karbantartása során.
  • Página 41 Leggerle subito! La Brooks Instrument progetta, fabbrica e collauda i propri prodotti in maniera tale che siano conformi ai vari standard nazionali ed internazionali. Tali apparecchiature devono essere installate, messe in esercizio e tenute in manutenzione in maniera adeguata affinché operino in conformità alle loro normali specifiche di funzionamento.
  • Página 42 P rliecinieties par to, lai pirms instrumenta tehnisk s apkopes b tu likvid ts procesa l nijas spiediens. Ja ir nepieciešams veikt k du da u nomai u, nodrošiniet, lai tiktu izmantotas „Brooks Instrument” nor d t s da as un da u nomai u veiktu kvalific ts person ls. Neat autu da u un proced ru izmantošana var ietekm s ražojuma sniegumu un samazin t procesa droš...
  • Página 43 25 mm arba 1 colio ar mažesni matuokliai atitinka tinkam inžinerijos praktik (SEP). Europoje taikomi elektromagnetinio suderinamumo (EMC) reikalavimai CE ženklu pažym ta „Brooks Instrument“ (elektrin / elektronin ) ranga buvo s kmingai išbandyta pagal elektromagnetinio suderinamumo reikalavimus (EMC direktyv 2004/108/EC).
  • Página 44 Urz dzenia pomiarowe o wielko ci 25 mm lub 1 cala lub mniejsze podlegaj zaleceniom „Uznanej Praktyki In ynierskiej” (SEP). Europejska dyrektywa dotycz ca kompatybilno ci elektromagnetycznej (EMC) Urz dzenia elektryczne / elektroniczne firmy Brooks Instrument posiadaj ce oznaczenie CE, przesz y pozytywnie testy pod k tem spe niania przez nich wymogów kompatybilno ci elektromagnetycznej (Dyrektywa EMC 2004/108/EC).
  • Página 45 Ler antes de proceder! A Brooks Instrument projecta, fabrica e testa os seus produtos de forma a satisfazer numerosas normas nacionais e internacionais. Estes equipamentos devem ser instalados, utilizados e mantidos de forma adequada, e devem funcionar dentro da sua gama de utilização. As instruções seguintes devem ser, durante a instalação, uso e/ou manutenção dos equipamentos da Brooks Instrument, apreendidas e integradas no plano de...
  • Página 46 În m sura în care indica iile c r ii ma inii nu sunt suficient de l muritoare, lua i leg tura cu reprezentantul Brooks Instrument pentru clarificarea problemei.
  • Página 47 Pre íta pred inštaláciou! Brooks Instrument svoje výrobky projektuje, vyrába a testuje takým spôsobom, aby tieto vyhoveli domácim aj medzinárodným normám. Tieto zariadenia je potrebné predpísaným spôsobom inštalova , prevádzkova a udržiava , na zabezpe enie ich spo ahlivej a normálnej prevádzky v celom pracovnom rozsahu.
  • Página 48 Najprej preberite jih Brooks Instrument tako konstruira, izdeluje in terstira svoje izdelke, da oni ustrezajo številnim doma im in mednarodnim standardom. Te naprave se morajo ustrezno instalirati, koristiti in vzdrževati, da vsekakor delajo ustrezno normalnom podro ju funkcioniranja. Naslednjih navodil se mora držati in potrebno je vgraditi v program varstva pri delu pri instaliranju, koriš...
  • Página 49 ¡Léalos primero! El Brooks Instrument proyecta, fabrica y prueba sus productos de manera que éstos respondan a numerosas normas nacionales e internacionales. Dichas instalaciones deben ser emplazadas, operadas y mantenidas adecuadamente, para que puedan marchar de todas formas en conformidad con el alcance normal de funcionamiento.
  • Página 50 Läs detta innan du fortsätter ! Brooks Instrument konstruerar, tillverkar och testar sina produkter med syfte att uppfylla alla nationella och internationella standarder. Dessa produkter måste installeras på rätt sätt, handhas och underhållas för att de skall fungera kontinuerligt enligt deras normala specifikation. De följande anvisningarna bör följas och integreras till Ert säkerhetsprogram varje gång när Brooks Instruments produkter installeras, handhas och underhålls.
  • Página 51 Installation and Operation Manual X-VA-1110-1140-eng Part Number: 541B040AAG ® Brooks 1110 and 1140 Series September, 2012 THIS PAGE WAS INTENTIONALLY LEFT BLANK...
  • Página 52 Europe +31 (0) 318 549 290 Asia +81 (0) 3 5633 7100 Due to Brooks Instrument's commitment to continuous improvement of our products, all specifications are subject to change without notice. TRADEMARKS Brooks ............Brooks Instrument, LLC Carboloy ............. General Electric Co.

Este manual también es adecuado para:

Full-view 1140

Tabla de contenido