choose the right place to apply the light pulse again, so as to avoid releasing
two pulses at the same area or leaving too much space between the treated
areas. The appliance recharges immediately after each pulse release. After
1.6 seconds (at intensity level 1), the Ready indicator lights up again. The
appliance is now ready to release another pulse.
Warning: Do not treat the same area of the skin more than once during one
treatment session. Re-treatment of the same area of the skin increases the risk
of side effects.
MODES
PRECISION mode
The Precision mode (described in the section above) allows safe treatment of
the most inaccessible and sensitive areas, such as face, armpits, bikini line, etc.
GLISS mode
Once the application surface of the appliance is properly applied to the skin
and you press and hold the Pulse release button, you can activate the Gliss
mode (continuous release of 36 pulses per minute, at intensity level 1). The
pulses are thus automatically released continuously without the need for
further manipulation. You can therefore simply move the device on the skin
without interruption in a slow and continuous motion, without lifting it up and
applying it to the skin again.
If you lift the appliance while holding the Pulse release button, the Gliss mode
remains active. However, for safety reasons, the pulse will not be released until
the device is in full contact with the skin. Make sure that the contact sensor,
which is around the periphery of the application surface of the appliance, is
firmly pressed against the skin so that the continuous flash function in the Gliss
mode is ensured. If you break the contact between the application surface of
the appliance and the skin, you have 5 seconds to apply the appliance back
on the skin and press it firmly while holding the Pulse release button. If the
appliance is not in full contact with the skin after 5 seconds, the Gliss mode will
deactivate and you will have to release the Pulse release button and press it
again to restart the process.
If you lift the appliance and release the Pulse release button, the Gliss mode
will deactivate.
The Gliss mode is suitable for users who already have some experience using
126
the device. Thanks to 36 pulses per minute (intensity level 1), the Gliss mode
allows you to treat larger areas of the skin, such as legs, back, arms, torso, etc.,
more safely and quickly. Use the Precision mode to treat sensitive areas and
facial skin.
AUTOMATIC SHUTDOWN FUNCTION
When not used for more than 10 minutes, the appliance automatically switches
off and the light indicator turns orange. If you want to restart the appliance,
press the On/Off button and set the required power.
COVERING OF THE TREATED SKIN
When releasing the pulses, proceed systematically in successive rows. This
method ensures better control of the pulses and helps you to cover the area
better while preventing treating the same area twice or releasing the pulses
too close to each other.
The pressure marks left on the skin after using the epilator will help you to
choose the right place to apply the light pulse again, so as to avoid releasing
two pulses at the same area or leaving too much space between the treated
areas. Avoid releasing more than one pulse on the same area of the skin during
one treatment session.
If burns or blisters appear on the skin, stop the treatment immediately.
FACE EPILATION
• You must wear safety goggles when treating your face with an epilator and
you must never look directly at the treated area during the pulse emission.
• Do not use the appliance to remove eyelashes, eyebrows or head hair.
• The appliance is not suitable for full removal of male beard.
• For your comfort and safety, we recommend asking someone to help you
with the first few treatment sessions.
• Use the PRECISION mode to remove facial hair. DO NOT USE THE GLISS MODE
TO TREAT FACE OR SENSITIVE AREAS.
• When treating your face, it is necessary to wait 5 seconds between each
pulse. The duration of the facial skin treatment session should not exceed
10 minutes.