Installation
- Finish plaster wall and tile up to the fitting template.
When doing so, seal wall openings against water
splashes.
• In the case of tiles laid in mortar, pointing must
be bevelled outwards.
• In the case of prefabricated walls, seal with
elastic sealing compounds.
- Remove fitting template (Y), see see fold-out page I
fig. [1].
Fit escutcheon, see figs. [1] and [2].
1. Push sleeve (A) with the mark (B) upward onto
mixer shank, make sure that the marking point (B1)
snaps into the sleeve (A), see fig. [1].
2. Fit escutcheon support (C) on the mixer, grease
seal (D) with the grease provided and slide onto the
sleeve (A), see fig. [2].
3. Place escutcheon (E) on the escutcheon sup-
port (C), hold in position and secure with screws (F).
4. Snap trim frame (G) into escutcheon (E).
5. For assembly of the thermostat handle, see chapter
"Adjustment".
If thermostat is installed too deep, the fitting
depth can be increased by 1 1/8" (27.5mm) with
extension set Part No. 47 461, see fold-out page II.
If the thermostat is installed too shallow, the fitting
depth can be reduced by 1/2" (12mm) with a spacer
Part No. 47 462 , see fold-out page II.
Adjustment
Temperature setting, see figs. [3] and [4].
• Before the mixer is put into service, if the mixed
water temperature measured at the point of
discharge varies from the specified temperature set
on the termostat handle.
• After each service on the thermostat mixer.
1. Open shut-off valve (H) and measure the
temperature of the water emerging with a
thermometer, see fig. [3].
2. Turn the green regulator nut (I) clockwise - counter-
clockwise with a screwdriver until the water em-
erging has reached a temperature of 100 °F (38 °C).
3. Fit the thermostat handle (J) so that the 100 °F
(38 °C) mark on the thermostat handle lines up with
the mark (B) on the sleeve (A), see fig. [4].
4. Insert fixing ring (K) and push decorative
sleeve (L) on the thermostat handle (J).
5. Push on decorative ring complete (M) or lever
complete and screw on handle cap (N).
The lever ring can be positioned in four positions.
Choose the best position suitable for the end user.
Reversed union (hot on right - cold on left).
Replace thermoelement (47 450), see replacement
parts fold-out page II, ref. No.: 47 282 - 1/2".
1
English
Temperature limitation
When in proper calibration, the temperature range is
limited to 110 °F (43 °C). There is a safety check
at 100 °F (38 °C).
If a higher temperature is desired, one can
exceed 100 °F (38 °C) by overriding the safety check.
Prevention of frost damage
When the domestic water system is drained, the
thermostat mixers must be drained seperately, since
check valves are installed in the hot and cold water
connections.
The complete thermostat assembly and check valves
must be unscrewed and removed.
Maintenance
For Maintenance, see figs. [5], [6] and fold-out page II.
Check, clean and if necessary, replace parts.
Grease with special valve grease (Cat. No. 18 012)
Shut off hot and cold water supplies.
I. Thermostat cartridge
1. Turn thermostat handle (47 427, 47 431) or lever
thermostat handle (47 432, 47 434) to the 100 °F
(38 °C) safety check, see fold-out page II.
2. Remove thermostat handle cap (47 428) and
decorative ring complete (47 429) or lever
complete (47 433).
3. Take out fixing ring (K).
4. Pull off thermostat handle (J).
5. Pull sleeve (A) from the mixer shank by pressing
down the tongue (S), see fig. [5].
6. Extract clamp (O).
7. Pull stop ring (P) until resistance is encountered
(approximately 3/8" [10mm]), see fig. [6].
8. Unscrew stop ring (P) complete with regulator
nut (I).
9. Remove escutcheon (47 459), see fig. [2] and
installation, Points 2 - 4, in reverse order.
10.Close both service stops (47 017, 47 467).
11.Unscrew thermostat cartridge (47 450, 47 582)
with 15/16" (24mm) open-ended spanner.
Temperature adjustment is necessary after each
service of the thermostat cartridge (see Adjustment).
II. Check valve
1. Proceed as for Maintenance of thermostat
cartridge, Points 1 - 4 and 8 - 10.
2. Unscrew check valve (14 116, 47 466)
with 11/16" (17mm) socket wrench or 3/8" (10mm)
socket spanner.
Reassembly in reverse order.
Replacement parts, see fold-out page II (* = special
accessories)
Care
Instructions for care of this fitting will be found in the
Limited Warranty supplement.