b. From the "Properties" column, select the "Modify" control to associate the program to the chosen
Multicast group (by default, all programs are associated to the same Multicast group – Group 1);
after setting all parameters, confirm them with the SAVE control.
c. Repeat the operation for each program to be sent to the network, making sure to associate a differ-
ent multicast group for each program;
IMPORTANT: for the correct functioning of the module, the 20Mbit/s maximum
through output for each SIG7730 module should not be exceeded (refer to the
MEASURE -> TOTAL BIT RATE menù on the TPE or WEB MANAGEMENT ->
PROGRAM LIST ->TOTAL BIT RATE on the WEB interface menù).