Troubleshooting Guide
3.
Unplug the unit, remove the cover of RMU (H) and check whether the
air hose is not disconnected from the air pump or pinched somewhere
along its length.
solution is no longer Clean
If solution is dirty, refer to section "RECOMMENDED PREVENTIVE
MAINTENANCE" and "ANNUAL MAINTENANCE" PAGE 13.
The bioremediation process may have been reduced or prevented by
the introduction of harmful or incompatible substances or an unfavorable
environment. Depending on the situation, replacing all or part of the
cleaning solution to re-start the system may be required.
Please contact the bio-CirCle
See page 20 for contact information.
solution odor
It is normal that the fresh solution may emit an apple odor. As oil and
grease are introduced into the cleaning solution, this odor will quickly
diminish leaving only a faint, pleasant scent. If the solution emits a strong
foul odor, ensure that the aeration system is functioning properly. Call the
bio-CirCle
®
technical support. See page 20 for contact information.
remoVing the remoVable multi-funCtion unit (rmu) (H)
To remove the RMU, follow these steps. Do so only for maintenance/
troubleshooting as described in this manual or if you were instructed by
Bio-Circle
personnel.
®
1.
Turn the unit off by unplugging it (E).
2.
Open the sink (G).
3.
Open the hose clamp that secures the hose and pull the hose from the
fitting (C).
4.
Lift up the RMU (H).
To put a RMU back in place, follow the above steps in reverse order.
Note: Store the RMU in the upside down position only. Ensure the RMU
is completely drained once removed.
(...continued)
®
technical support before proceeding.
Compact-S Model 350 - Parts Cleaning System
15