Start Up Instructions
Please be sure to read and observe, the "SAFETY INSTRUCTIONS" at the
beginning of this manual. Detailed start-up instructions can also be found at
www.biocircle.com.
Remove the bio-CirCle
1.
and check for any shipping damage. Should any be detected, DO NOT
connect the machine but report the damage to the transport carrier and
to Walter. Important: The original packaging must be retained.
2.
Open the sink (G), a sink holder bracket (N, page 12) is located
towards the rear left side to maintain the sink in the open position.
•
Remove all packaging material around the unit and from inside the
tank. (Ex.: from underneath or behind pump/heater coil).
•
Ensure filter bowl (D) is tightened if equipped. (Hand tighten only),
(sold separately as an accessory).
Place unit indoors, on a smooth level surface away from exposure to direct
sunlight. use only genuine bio-Circle aero™ (55-A 207, 20 liters/5.3gal.
or 55-A 208, 208 liters/55 gal.) bio-Circle l™ (55-A 007, 20 liters/5.3 gal.
or 55-A 008, 208 liters/55gal.) and bio-Circle ultra™ (55-A 107,
20 liters/5.3 gal. or 55-A 108, 208 liters/55gal.) cleaning solution.
When filling the unit from a drum, ensure the transfer pump being used is
clean and close the drum.
Fill the tank to normal operating capacity of up to 120 liters/31.7 gal. Refer
to level lines within the tank as shown on page 10.
Note: Open the container and pour slowly to prevent splashing and
excessive foaming of Bio-Circle Aero™, Bio-Circle L™ or Bio-Circle
Ultra™ liquid. If the container has a vent hole, open prior to pouring.
3.
Plug power cord into properly grounded 3-prong, 120V, 60Hz, outlet
protected by a class A GFCI.
Allow the heater coil to warm bio-Circle aero™, bio-Circle l™ or
4.
bio-Circle ultra™ solution to working temperature to optimize cleaning
efficiency. This can take up to 2 or 3 hours.
Once the solution has reached its proper working temperature of
41ºC/106°F, the heater will turn off. Periodically, the heater will turn ON
automatically to maintain the proper working temperature.
Note: Do not plug in either the main power switch or the cleaning pump
switch (E) with no liquid inside the machine.
never unplug the bio-CirCle
8
Compact-S Model 350 - Parts Cleaning System
®
Parts Cleaning System from its packaging
unit except for servicing.
®