MAINTENANCE

The maintenance of the air conditioner is quite limited.
Do not leave idle for a long time but start the air conditioner at least once a month even in winter,
since the operation ensures the lubrication of some components that would dry out if left idle for a
long time.
The outer cover and internal air diffuser should be cleaned periodically, using a damp cloth to
remove dust. If necessary, use a mild detergent. Do not use gasoline or solvents.
It is sufficient to clean the condenser coil annually (by removing the outer cover) with compressed
air, taking care not to damage the aluminum fins.
On them, insects, lint, and other bodies can be deposited, leading to a reduction in the efficiency
of the heat exchanger.
At the same time it is advisable to check the operation of the condenser electric fan.
It must be kept in mind that cleaning the condenser and checking that it is properly ventilated are
extremely important operations. In fact, a very dirty or unventilated condenser not only causes a
reduction in the performance of the air conditioning system, but it may also cause a reduction in the
life of the compressor or even break it.
Once every two months, it is necessary to clean with compressed air, the filters "B.2" on the sides
of the air diffuser (fig. 06).
It is advisable to replace the filters every year.
It is advisable to avoid operating the air conditioner without filters, as dirt may accumulate on the
evaporator coil causing a reduction in the efficiency of the system.
The air conditioner is supplied loaded with refrigerant and tested. The refrigerant used is R134a and
the load is: see TECHNICAL FEATURES.
The hermetically cooling system is subjected to careful control to detect any anomalies and gas
leaks.
Before performing any work or maintenance involving the removal of the roof
unit cover and the air diffuser, which may result in contact with electrical parts,
DISCONNECT the vehicle battery and DISCONNECT any 230V power supply.
If there is a rooftop air conditioner, never drive your camper-van into an automatic
wash station.
Any repairs or work on refrigerant charging and recovery must be carried out by
authorized IndelB workshops and qualified personnel.