1) By pressing any button must be according to"The
Effectiveness of Functional Buttons" on page 8.
2) The Hold function will be cancelled if the Meter is
activated by pressing the HOLD button.
To disable the Sleep Mode function, press and hold
HOLD button while turning on the Meter.
SPECIFICATIONS
A. General Specifications
Maximum voltage including transient overvoltage between any
terminals and grounding: 600 V rms
Display: 3 1/2 digits LCD display, Maximum display 1999
Auto Polarity Display Overloading: Display OL or –OL
Battery Deficiency: Display
Measurement Speed: Updates 3 times/second
Measuremnet Deviation: When the conductor being meaured is not
placed in a correct position during AC current measurement, it will
cause 1% reading deviation
Drop Test: 1 meter drop test passed
Max. Jaw Size: 28 mm diameter
Projected Max. Current conductor size : 26 mm diameter
Power : 2 pcs of 1.5 V batteries (AAA)
Battery Life : typically 150 hours (alkaline battery)
Sleep Mode (can be disabled)
Dimensions (H x W x L) : 30 mm x 76 mm x 208 mm
Weight : Approximate 260 g (batteries included)
B. Environmental Restrictions
The Meter is suitable for indoor use.
Altitude : Operating: 2 000 m Storage: 10 000 m
Safety/ Compliances: IEC 61010 CAT.II 600V, CAT.III 300 V over voltage
and double insulation standard.
Temperature and humidity:
Operating: 0° C ~ 30° C (≤75% R.H); 30° C ~ 40° C (≤70% R.H); 40° C ~
50° C (≤45% R.H); Storage: -20° C ~ +60° C (≤75% R.H)
E N G L I S H
31