ACCURACY SPECIFICATIONS
Accuracy: (a% reading + b digits), guarantee for 1 year.
Operating temperature: 23°C + 5°C
Relative humidity: 75%R.H
Temperature coefficient: 0.1x (specified accuracy) /1°C
A.
AC Voltage: Auto ranging
Range
2 V
20 V
200 V
600 V
Remark: Input impedance: 10MΩ //<100pF" Displays effective value of sine wave
(mean value response). Frequency response: 40Hz~1kHz. To adjust reading in
accordance with effective value
B.
DC Voltage: Auto ranging
Range
200 mV
2 V
20 V
200 V
600 V
Remark: Input impedance: 10MΩ
C.
Resistance: Auto ranging
Range
200 Ω
2 kΩ
20 kΩ
200 kΩ
2 MΩ
20 MΩ
Remark: Input impedance: 10MΩ
D.
Continuity Test
Range
Remark:
Open circuit voltage approximate 0.45 V The buzzer may or may not beeps when
the resistance of a circuit under test is between 50 Ω and 120 Ω The buzzer may
not beep when the resistance of a circuit under test is greater than 120 Ω
32
Resolution
1 mV
10 mV
100 mV
1 V
Resolution
0.1 mV
1 mV
10 mV
100 mV
1 V
Resolution
100 mΩ
1 Ω
10 Ω
100 Ω
1 kΩ
10 kΩ
Resolution
Around ≤50 Ω the
100 mΩ
Accuracy
Overload Protection
± (1.2%+5)
± (1.5%+5)
Accuracy
Overload Protection
± (0.8%+3)
± (0.8%+1)
± (1%+3)
Accuracy
Overload Protection
± (1%+2)
± (1.2%+2)
± (1.2%+2)
± (1.5%+2)
Accuracy
Overload Protection
buzzer beeps
600 V rms
600 V rms
600 V p
600 V p