Test items
Setting Method
Keep pressing the "LOCK"
and "FRZ.
TEMP" button for 3 seconds
and release
Enter Test
Mode
After entering into test
mode, if no button is
pressed within 30 seconds
Enterinto test mode and
press "FRZ. TEMP" button for
the first time
Select to enter
into forced
In forced cooling mode, if
cooling mode
no button is pressed within
36 hours,
Enter into test mode and
press "FRZ. TEMP" button for
the second time
In forced defrosting mode,
when the defrosting sensor
reach a temperature of
7°C and the defrosting
Select to enter
heater has been working
into forced
for at least 2 minutes.
defrosting
mode
In forced defrosting mode,
if the temperature of
defrosting sensor is always
lower than 12°C and the
defrosting heater has been
working for 60 minutes,
Select to
enter into ice
Enter into test mode and
maker forced
press "FRZ. TEMP" button for
operation
the third time.
mode
Enter into test mode and
Select to exit
press button for the four
the test mode
time
9.9 Demo mode (None)
9.10 Backup data for power fail
1) The running state of the refrigerator is remembered after compressor running for 1 hour continuously.
2) The running state of the refrigerator is remembered after change function settings and lock.
3) When the refrigerator is out of power and recharged, the running state of the refrigerator is same as before.
Setting result
LED indicators display "0", then the refrigerator enters
into test mode
then the refrigerator will exit the test mode and return
to normal operation mode
LED indicators display "1", then the compressor and the
fan will start working
then the refrigerator will exit the test mode and return
to normal operation mode
LED indicators display "3", then the compressor and the
fan will stop working, defrost heater starts to work.
then the refrigerator will exit the test mode and return
to normal operation mode
LED indicators display "4", then ice maker motor will
turn ice twice, water valve starts to supply water to ice
maker.
LED indicators display "0", then the refrigerator will exit
the test mode and return to normal operation mode
105