Waeco CoolMatic CB-36 Instrucciones De Uso página 26

Frigorífco empotrabe por compresor
Ocultar thumbs Ver también para CoolMatic CB-36:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 51
Installing and connecting the cooling device
➤ Determine the required cross section of the cable in relation to the cable
length according to fig. 5, page 4.
Key for fig. 5, page 4
Co-ordinate axis
l
Caution!
e
Make sure that the polarity is correct.
➤ Connect the red lead to the positive terminal.
➤ Connect the black lead to earth.
➤ Before starting up the device for the first time, check whether the operat-
ing voltage and the battery voltage correspond (see type plate).
➤ Connect the cooling device
– As directly as possible to the pole of the battery or
– To a plug socket which is fused with at least 15 A (at 12 V) or 7.5 A (at
24 V).
Caution!
e
Disconnect the cooling device and other power consuming devices
from the battery before connecting the battery to a quick charging
device.
Overvoltage can damage the electronics of the device.
The cooling device is equipped with an electronic device to protect against
reversing the polarity and short circuits when connecting to a battery.
To protect the battery, the cooling device switches off automatically if the volt-
age is insufficient (see table below).
Switch-off voltage
Switch-on voltage
26
Meaning
Cable length
Cable cross section
12 V
10.4 V
11.7 V
CB-36, CB-40, CB-110, RHD-50
Unit
m
mm²
24 V
22.8 V
24.2 V

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Coolmatic cb-40Coolmatic cb-110Coolmatic rhd-50