Indicator lamp for rotation direction
will blink (3-phase appliances only)
Figure 14
Exchange the poles at the appliance
plug.
Indicator lamp "Ready for use"
turns off
– No line voltage, see "Appliance is not
running".
Indicator lamp service
Indicator lamp service will be
illuminated
– Lack of oil
Replenish oil.
1x blinking
– Water shortage
Check water supply, check connec-
tions.
– Leak in the high pressure system
Check high pressure system and con-
nections for tightness.
2x blinking
– Fault in the voltage supply or current
pickup of the motor too high.
Check main connections and mains
fuse.
Inform Customer Service.
3x blinking
– Engine overload/overheat
Set the appliance switch to "0/OFF".
Allow device to cool down.
Turn on the appliance.
– Error occurs repeatedly.
Inform Customer Service.
4x blinking
– The exhaust temperature limiter has
been triggered.
Set the appliance switch to "0/OFF".
Allow device to cool down.
Turn on the appliance.
– Error occurs repeatedly.
Inform Customer Service.
5 x blink
– Obstructed reed switch in the lack of
water fuse or magnetic piston stuck.
Inform Customer Service.
6 x blink
– The flame sensor turned the burner off.
Inform Customer Service.
Fuel indicator lamp glows
– Fuel tank empty.
Refill fuel.
Indicator lamp system care is
– System care bottle empty.
Replace the system care bottle.
Indicator lamp for detergent glows
– Detergent tank is empty.
Refill detergent.
Appliance is not running
– No power
Check power connection/conduit.
Device is not building up pressure
– Air within the system
Vent pump:
Set dosing value for detergent to "0".
With open hand spray gun turn device
on and off multiple times with the device
switch.
Open and close the pressure/quantity
regulation at the pump unit with the
hand spray gun open.
Note: By dismantling the high pressure
hose from the high pressure connection the
venting process is accelerated.
If detergent tank is empty, refill.
Check connections and conduits.
– Pressure is set to MIN
Set pressure to MAX.
– Sieve in the water connection is dirty
Clean sieve.
Clean the fine filter; replace it, if neces-
sary.
– Amount of water supply is too low.
Check water supply level (refer to tech-
nical data).
EN
– 11