VIDEOPORTERO 2 HILOS | 2-WIRE VIDEO DOOR ENTRY SYSTEMS | VIDÉO-PORTIER 2 FILS
EXTERNAL ENTRANCE PANEL CONSISTING OF 2 PANELS IN PARALLEL, EACH OF
B
THEM FOR 12 DWELLINGS
Assigning Pushbuttons
Flats
8
6
4
2
8
6
4. Steps for assigning pushbuttons to buildings
(A) Set microswitch 3 of the SW1 switch of the main module to the ON position (i.e. the left
position).
(B) Press the right pushbutton on the bottom row of pushbuttons a single time. By doing
so this pushbutton is assigned to dwelling number 1 (i.e. the dwelling whose telephone/
connection bracket has been programmed with code number 1) of building number 1.
(C) If the building in question is a detached single-family house, press this same pushbutton
again. If there are several dwellings, press the pushbutton corresponding to the last dwelling
of this building. The pushbuttons corresponding to building number 1 have now been recorded
by the main module.
(D) Press once only, the pushbutton immediately following the one pressed in the last step. By
pressing this pushbutton, it is assigned to dwelling number 1 of the following building. Note:
If you do not press the pushbutton immediately following the one pressed in step 1, the panel
will emit beeping tones to indicate the error. See Note.
(E) If the building in question is a detached single-family house, press this same pushbutton
again. If there are several dwellings, press the pushbutton corresponding to the last dwelling
of this building. The pushbuttons corresponding to the building have now been recorded by
the main module.
(F) Repeat steps D and E for each of the buildings until all the pushbuttons of the external
entrance panel have been assigned.
(G) Once all the pushbuttons of the external entrance panel have been assigned, set
microswitch 3 of the SW1 switch to the OFF position (right position). Check that the
pushbuttons have been properly assigned by making calls from the external panel. If they
have not been correctly assigned, go back to the beginning.
Note: If an error is caused by pressing the wrong pushbutton or for some other reason, set microswitch 3
of the SW1 switch to the OFF position (left position) and begin again from the beginning.
Detail: joining of pushbutton compartments
7
5
Building 3
3
1
7
Building 2
5
Flats
4
Building 2
2
8
6
Building 1
4
2
3
1
7
5
3
1
67