The (SIG7120 or SIG7121) module programming is carried out by using the universal TPE programmer by which
all the main functioning parameters can be set.
To program by means of the TPE, it is sufficient to connect the programmer to the interconnection module
(SIG7900) of the New HeadLine. After waiting for the automatic scanning of all the modules in the headend, it will
be possible to access all the available modules as well as the module to be programmed. Refer to the paragraph
"HEADEND SETUP MENU AND KTP EMULATION".
IMPORTANT: After connecting the module to the panel, wait for the start-up phase and the system configura-
tion to be completed. It will take about 30 seconds to correctly identify the module. If, during the programming,
the TPE often shows the word "Wait ..." (for example during the scrolling of the channel list), it can be useful
to increase the TIMEOUT value (30) of the TPE programmer (set by default at 12 seconds). To do that, enter the
"SETUP TPE" – "TIMEOUT COM" menu (refer to the SETUP TPE menu).
IMPORTANT: by using the SIG7905 interface (Controller Host module), it is possible to check the status
of the module and program it remotely. For further information, refer to the instructions of the SIG7905
module.
IMPORTANT: to save the set parameters, press the
minutes from the last modification, the set data will be lost and the previous values will be restored.
For further analysis of the TPE functions and menu, see the following paragraph.
Refer to the legend of the following tables for information relevant to programming activities and the interpretation
of the programming menus indicated in the flow-charts.
TPE keys
......
Graphic indications of
the menu diagrams
5. PROGRAMMING INSTRUCTIONS
To confirm an entered value or to select a menu
To cancel an entered value or exit a menu
To scroll through menu items
Select the menu by using
Scroll the menu to the right
Scroll the menu upwards
Scroll the value to the right
22
key of the TPE. If the key is not pressed within 5
Key Function
To enter values
To save the modifications
Meaning
or
keys and exit with the
or to the left
or downwards
or to the left
key