All manuals and user guides at all-guides.com
Battery Charging Status LEDs
Condition
No battery pack installed
Charge cycle in progress
Charge cycle complete
Fault condition
A fault condition occurs if the battery temperature is outside the
normal operating temperature for the charger. The fault clears
and charging resumes when the battery temperature returns to
the normal operating range. If a fault condition does not clear
under normal operating temperature range, this may indicate a
defective battery.
Power Usage
Each charger power supply (model 073573) uses approximately 1
amp of current. You can have 20 battery pack chargers plugged
into one 20-amp circuit assuming no other loads are drawing off
that circuit breaker.
Electrical Rating
• Quad Charger (Model AC13) 12 VDC @ 4.15A
• Power Supply ( Model 073573) AC 100-240 VAC, 47-63 Hz
@ 1A
Where to Find More Information
Visit the Intermec web site at
our current manuals (in PDF). To order printed versions of the
Intermec manuals, contact your local Intermec representative or
distributor.
Visit the Intermec technical knowledge base (Knowledge Cen-
intermec.custhelp.com
tral) at
or to request technical support for your Intermec product.
LED State
Off
Red
Green
Yellow
www.intermec.com
to review technical information
to download
3