AMPERESTOP FORCE (WHITE)
Regulation of force. Turn left to decrease and right to increase.
NOTE: IF THE SPEED OF THE SOFT STOP IS THE SAME AS THE REST
OF THE MANEUVER, TIGHTEN THE SCREW LOCATED BELOW THE
CONTROL PANEL UNTIL THE ADEQUATE SPEED IS REACHED.
MOTOR TYPE (C S )
Left selector – More than 600kg motor.
Right selector – Less than 600kg motor.
1 CLOSE BY PHOTOCELL
ON: : Start the closing maneuver once the photocell is cut and spend 5 seconds.
OFF: Door work normal.
2
AUTOMATIC CLOSE
Automatic closure activated. Once opened, door closes automatically after waiting
ON:
the programmed time. Also if DIP1 is activated. The closing maneuver begins once the
time has elapsed or after 5 seconds have elapsed since the photocell is cut.
YACO 800 / 1500 KG
SELECTORS
OPTIONS