Floor drain system
For floor drain installations, you will need to remove the drain
hose U-form on end of drain hose.
Floor drain system requires a Siphon Break Kit (Part Number
285320). Minimum siphon break: 28" (710 mm) from bottom
of washer. Additional hoses may be needed.
Laundry tub drain system
8"
39"
(203 mm)
(990 mm)
Minimum capacity: 20 gallon (76 L). The top of the laundry tub
must be at least 39" (990 mm) above floor.
ELECTRICAL REQUIREMENTS
A 120 V, 60 Hz, AC only, 15 or 20 A, fused electrical
n
supply is required. A time-delay fuse or circuit breaker is
recommended. It is recommended that a separate circuit
breaker serving only this appliance be provided.
This washer is equipped with a power supply cord having a
n
3 prong grounding plug.
To minimize possible shock hazard, the cord must be
n
plugged into a mating, 3 prong, grounding-type outlet,
grounded in accordance with local codes and ordinances. If a
mating outlet is not available, it is the personal responsibility
and obligation of the customer to have the properly grounded
outlet installed by a qualified electrician.
6
If codes permit and a separate ground wire is used, it is
n
recommended that a qualified electrician determine that the
ground path is adequate.
Do not ground to a gas pipe.
n
Check with a qualified electrician if you are not sure the
n
washer is properly grounded.
Do not have a fuse in the neutral or ground circuit.
n
INSTALLATION INSTRUCTIONS
It is necessary to remove all shipping materials for proper
operation and to avoid excessive noise from washer.
1. Move washer to within 4 ft (1.2 m) of its final location; it must
be in a fully upright position.
NOTE: To avoid floor damage, set washer onto cardboard
before moving it and make sure lid is taped shut.
48"
(1.2 m)