COMBUSTION HEAD ADJUSTMENT

Adjusting screw A modifies the position of the line choke/deflector with regards to the flow nozzle, thereby
varying the opening of the air intake.

AIR INTAKE ADJUSTMENT

The motor reducer controls the air intake valve. Adjustment of the open/close position of the 1° flame / max.
opening is controlled by turning the cam anti-clockwise to open the butterfly valve and clockwise to close.
Blue cam
totally closed
Orange cam
air control 1° flame
Red cam
air control 2° flame
Black cam
Permits opening of the
electromagnetic valve of
the 2° flame
Servocontrol type SQN 70...