EGAmaster 65512 Manual De Instrucciones página 16

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

If the distance more than 3 mm, please refer to the following adjustment method.
The method for Y direction check is same as X direction check, which requires you to
replace X1 & X2 with Y1 & Y2 facing the wall.
Horizontal calibration
Turn I/O key on before switching to calibration mode, and the unit will be self-leveled, at the
same time, the rotor is rotating.
Press and hold the cal key for more than 5 seconds, and then release this key to stop the
rotor from rotating.
That the X LED1 blinks fast in green is to indicate X direction calibration is in progress.
Then press the spot key on the unit or remove control to bring the laser beam to the center
of the reference point A and B. Please be noted that it is preferable to press and hold spot
key to help you to fine tune the laser beam to desired position. If there is still a bit from
accessibility, you may reach for it by slightly turning the unit.
Bring the laser point to the center of the reference point A and B by pressing slope key
briefly. If X2 faces one wall and the laser beam is projected in the reference direction, move
down the laser beam by pressing
After appropriate adjustment then press the cal key twice, the unit will save and quit the cal
mode.
Steps for Y direction calibration are same as those for X direction calibration. Please be
noted to adjust it after entering Y direction calibration mode (LED2 blinks in red), and
adjustment will be saved by pressing cal key only once. If Y1 faces one wall and the laser
beam is projected in the reference direction, move down the laser beam by pressing
slope key.
Press slope key every 5 times, the laser beam 20m away can be moved up and down by
All manuals and user guides at all-guides.com
of slope key.
of

Publicidad

Tabla de contenido
loading

Tabla de contenido