14.2 Speed Fitting Removal
Hold the grey ring tight against the body of the speed fitting and pull out the hose.
WARNING: If you do not hold the grey ring but pull at the hose, the speed fitting will cut
even deeper into the hose.
WARNING: Hoses must not be pressurised during removal.

15. TEMPERATURE AND ADJUSTMENT

The temperature of the cooled beverage is controlled by a mechanical thermostat in
temperature range of 2 °C to 8 °C. The thermostat has a numerical scale of 1-7.
WARNING: If you are using the cooler to cool non-alcoholic beverages, set the thermostat
knob to 5 at the most, otherwise, there is a risk of the beverage freezing in the cooler's tubing
and damaging the device.

16. KEG TAPPING AND UNTAPPING

16.1 Keg Tapping
Procedure for tapping a keg using an S-system keg coupler.
16.2 Keg Untapping
Procedure for untapping a keg using an S-system keg coupler:
16.3 Keg Tapping
Procedure for tapping a keg using an A-system keg coupler:
16.4 Keg Untapping
Procedure for untapping a keg using an A-system keg coupler:
WARNING: Make sure the adapter is clean before tapping the keg!
(see Fig. 15.)
Max. Inlet beverage temperature 25 °C.
:
(see Fig. 16.)
: