Electrical
WARNING: Risk of electric shock. Can shock, burn or kill. Plug the pump into a 115 Volt, 60HZ, Ground Fault Circuit
Interrupter (GFCI) protected grounded outlet only. The pump is equipped with a 3-wire, grounded, cord and plug. Do not
modify or remove the plug. Make sure the pump circuit meets the National Electrical Code (in USA) or the Canadian
Electrical Code (in Canada). To avoid dangerous electrical shock hazard, keep the cord dry at all times.
Pump Service
WARNING: Risk of electric shock. Can shock, burn or kill. Can shock, burn, or cause death. Unplug the pump before
servicing it. Do not handle the pump or attempt to work on the pump with wet hands or while standing on a wet or damp floor.
The motor has an auto-reset thermal overload protector. If the motor overheats, the overload will cut off the power to prevent
damage and will reset after the motor cools. If the overload trips repeatedly, check the pump for the cause (low voltage, a
clogged impeller, etc.).
CARE AND CLEANING
DANGER!
Potential hazard that will result in serious injury or loss of life.
Disconnect power supply, drain all water and release all pressure from the water system before attempting to install,
service, relocate or perform any maintenance.
Do not attempt to repair the motor. Have the motor repaired at a licensed or certified electrical motor repair shop.
Draining the pump
1. Unplug the pump from power supply outlet.
2. Remove drain plug close to the inlet hole and air plug located on the top of the pump close to the outlet hole, to vent the
piping system
3. Drain all piping to a point below the freeze line. This will drain the pump.
Note: While this will drain the pump, it will not necessarily drain all the unprotected parts of the piping system.
drain plug
6