PERFORMANCE
Model
62051
61041
SAFETY INSTRUCTIONS
1.
Do not pump flammable or explosive liquids such as oil, gasoline, kerosene, ethanol, etc. Do not use in the presence of
flammable or explosive vapors. Using this pump with or near flammable liquids can cause an explosion or fire, resulting
in property damage, serious personal injury, and/or death.
2.
ALWAYS disconnect the power to the pump before servicing.
3.
Do not touch the motor housing during operation. The motor is designed to operate at high temperatures. Do not
disassemble the motor housing.
4.
Do not handle the pump or pump motor with wet hands or when standing on a wet or damp surface, or in water before
disconnect the power.
5.
Release all pressure and drain all water from the system before servicing any component
6.
Secure the discharge line before starting the pump. An unsecured discharge line will whip, possibly causing personal
injury, and/or property damage.
7.
Extension cords may not deliver sufficient voltage to the pump motor. Extension cords present a life threatening safety
hazard if the insulation becomes damaged or the connection ends fall into water. The use of an extension cord to power
this pump is not permitted.
8.
Wear safety goggles at all times when working with pumps.
9.
This unit is designed only for use on 115 volts (single phase), 60 Hz, and is equipped with an approved 3-conductor
cord and 3-prong grounded plug. Do not remove the ground pin under any circumstances. The 3-prong plug must be
directly inserted into a properly installed and grounded 3-prong, grounding-type receptacle. Do not use this pump with
a 2-prong wall outlet. Replace the 2-prong outlet with a properly grounded 3-prong receptacle (a GFCI outlet) installed
in accordance with the National Electrical Code and local codes and ordinances. All wiring should be performed by a
qualified electrician.
10. Protect the electrical cord from sharp objects, hot surfaces, oil, and chemicals. Avoid kinking the cord. Do not use
damaged or worn cords.
11. Failure to comply with the instruction and designed operation of this unit may void the warranty. ATTEMPTING TO USE
A DAMAGED PUMP can result in property damage, serious personal injury, and/or death.
12. Ensure that the electrical circuit to the pump is protected by a 20-amp or larger fuse or circuit breaker.
13. Do not lift the pump by the power cord.
14. Know the pump and its applications, limitations, and potential hazards.
15. Secure the pump to a solid base. This will aid in keeping the pump in a vertical orientation. This is critical in keeping the
pump operating at maximum efficiency. It will also help prevent the pump from clogging resulting in premature failure..
16. Periodically inspect the pump and system components. Disconnect the pump from the power supply before inspecting.
17. Follow all local electrical and safety codes, along with the National Electrical Code (NEC). In addition, all Occupational
Safety and Health Administration (OSHA) guidelines must be followed.
HP
0 ft.
5 ft.
3/4
10
9.4
1/2
9.3
8.2
Flow Rate
(GPM) at 30psi
discharge pressure
10 ft.
15 ft.
20 ft.
8.8
8.0
6.8
7.6
6.0
5.6
2
Max. Pressure
25 ft.
5.4
66PSI
4.2
62PSI