GAS CONNECTION
Important
Those authorised to carry out this opera-
tion must have experience acquired and
certified in the specific sector, must make
the connection to the proper standards,
and must comply with all the relevant regu-
lations and legislation. Once the connec-
tion has been made, before the appliance is
put into operation a general check must be
made to ensure there are no gas leaks.
To make the connection, connect the mains line to
the appliance's connection pipe, fitting a shut-off
tap (A), to allow the gas supply to be cut off when
necessary.
Important
The tap (A), not supplied with the appliance,
ELECTRICAL CONNECTION
Important
The connection must be made by author-
ised, skilled personnel, in accordance with
the relevant legal requirements, using ap-
propriate and specified materials. The ap-
pliance is supplied with operating voltage
230V/1N.
Caution - warning
Before doing any work, cut off the mains elec-
tricity supply.
B
A
must be installed in an easily accessible
position and its status (on or off) must be
obvious at a glance.
Connect the appliance to the mains electricity
supply as follows.
1 - If not already present, install a circuit-breaker
(A) with overload cutout and differential safety
breaker close to the appliance.
2 - Pull off the knob (B).
3 - Undo the screws (C) and remove the control
panel (D).
4 - Fit the power supply cable into the cable gland
(E).
F
C
D
- 19 -