4. WIRING INSTRUCTIONS

RJ45 Ethernet Cable
The Ipercom system has been designed to work with the EIA/TIA 568B standard.
Plug the cable into one of the RJ45 connectors with the Urmet logo.
Insert the wire in its guide, according to the provided colour code (Standard T568B).
Grey sheath
Cut the cables so that they protrude from the guide by about 5 mm, insert the guide in its plug and crimp
with the specially provided tool.
Make sure that the grey sheath stays inside the plug. This type of connection will NOT guarantee double
insulation.
Connect one end of the Ethernet cable to the POE switch of the system and the other end to the LAN
connector of the device.
4.1
DISTANCES AND WIRE CROSS-SECTION AREAS
Type of connection
Floor call
Panic Alarm
Call repetition
LAN
Wires with cross-section area of 0.5 mm
cross section area smaller than 0.5 mm
(#) To ensure operation of the video door phone at maximum distances, the wire must be in Category 5e
and the section of the twisted pairs must be AWG24.
The maximum resistance of the individual wire must not exceed 10ohm/100m.
The wire must comply with the following standards:
- EIA/TIA 568-B.2 or EIA/TIA 568-C.2
- EN50288 3-1
- IEC 61156-5
The connection between the IP video door phone and POE switch must be made using a single wire
without the use of additional patch cords.
8
Wire
No.
1
White-Orange
2
Orange
1
3
White-Green
4
Blue
8
~ 5 mm
1
8
Max distance
or larger must comply with IEC 60332-1-2; wires with
2
must comply with IEC 60332-2-2.
2
Cable colour
Plug
1
8
30 m
30 m
30 m
100 m
Wire
Cable colour
No.
5
White-Blue
6
Green
7
White-Brown
8
Brown
Min - max section
0,5 - 1 mm
2
0,5 - 1 mm
2
0,5 - 1 mm
2
CAT5e (#)
DS1741-001