Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
Do not allow the streams of the shower touch sensitive
body parts (such as your eyes). An adequate distance
must be kept between the shower and you.
The hot and cold supplies must be of equal pressures.
Assembly (see page 34)
Important! The fitting must be installed, flushed and
tested after the valid norms.
Important! Do not use silicone containing acetic acid!
With maximum mounting depth of the basic set of 10mm
between upper border of bath tub and lower border
mixer,an optional extension adapter can be obtained
seperately (article number 27423000) from Hansgrohe
should the distance be more (see page 3).
Operation
The mixer is activated by lifting the lever handle.
Turning to the left = warmer water,
turning to the right = cooler water.
The flow is changed from bath to shower function by
pulling the knob at the upper side of the spout. After
shutting off the water flow, the mixer returns automatically
to the bath function.
Fault
Insufficient water
Mixer stiff
Mixer dripping
Hot water temperature too low
Instantaneous heater didn't work
English
Technical Data
Operating pressure:
Recommended operating pressure:
Test pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
anti-pollution function
To adjust the hot water limiter on single lever mixers, please
see page 35.
No adjustment is necessary when using a continuous flow
water heater.
Hansgrohe mixers can be used together with hydraulically
and thermically controlled continuous flow heaters if the
flow pressure is at least 0,15 MPa.
Spare parts (see page 4)
Cleaning (see page 36)
Cause
- Shower filter seal dirty
- Non return valve hasn't moved back - Exchange non return valves
- Cartridge defective, calcified
- Cartridge defective
- Hot water limiter incorrectly set
- Flow limiter in handshower isn't
removed
- Filters are dirty
- Non return valve hasn't moved back - Exchange non return valves
Remedy
- Clean filter seal between shower and
hose
- Exchange cartridge
- Exchange cartridge
- Set hot water limiter
- Remove flow limiter
- Clean the filter / exchange filter
max. 1 MPa
0,1 – 0,5 MPa
1,6 MPa
max. 80° C
65° C