Stationary Air Compressor
Installation
(Con't)
UNITS WITH LINE CORDS ONLY
In the event of an electric short circuit,
grounding reduces the risk of electrical
shock by providing an escape wire for
the electric current. This product is
equipped with a cord having a
grounding wire with an appropriate
grounding plug. The plug must be
plugged into an outlet that is properly
installed and grounded in accordance
with all local codes and ordinances.
Improper use of grounding
plug can result in a risk of
electrical shock. Do not use
grounding adapter.
2. If repair or replacement of the cord
or plug is necessary, do not connect
the grounding wire to either flat
blade terminal. The wire with
insulation having an outer surface
that is green with or without yellow
stripes is the grounding wire.
3. Check with a qualified electrician or
serviceman if the grounding instructions
are not completely understood, or if in
doubt as to whether the product is
properly grounded. Do not modify the
plug provided; if it will not fit the outlet,
have the proper outlet installed by a
qualified electrician.
PLUGS AND RECEPTACLES
1. If the plug on the electrical cord of
the unit is unfamiliar to you or will
not fit your particular receptacle,
Figure 4 will help you understand
why by illustrating the different
plugs and the voltages they are to
be used with.
2. Make sure that the product is
connected to an outlet having the
same configuration as the plug.
3. The receptacles must be connected
to circuits rated to carry at least the
voltage and amperages shown.
4. NEVER have a receptacle replaced
with one of a higher amperage
before determining the change can
be made according to all electrical
codes affecting your particular area.
PLUG AND CORD GAUGES FOR 120 VOLT OPERATION
Amps
Not more than 15
Over 15 - 18
Over 18 - 20
Over 20 - 25
The installation should be made by
a qualified electrician. If the
products must be reconnected for
use on different types of circuits,
the re-connection should be made
by qualified personnel.
DUAL VOLTAGE MOTORS (SOME
MODELS)
The grounding plug
NOTICE
!
must be changed
to convert unit for dual voltage.
Dual voltage motors may be connected
for either 120 volts or 240 volts. By
comparing the plug on the cord with
the receptacles shown below, you can
determine for which voltage your
compressor is factory wired. Also check
motor decal to change from low
voltage to high voltage.
All wiring must be
completed by a
qualified electrician.
To change connections for alternate
voltage:
1. Disconnect cord from power source
2. Remove motor terminal cover.
3. Find connection diagram on back
side of the cover or on motor
nameplate and reconnect to desired
voltage as indicated on diagram.
4. Change plug to match voltage and
current requirements.
When converting
to an alternate
voltage, be sure the green ground wire
of the cord connects to the ground pin
of the plug and to the metal body of
the pressure switch.
Assembly
ADDITIONAL HARDWARE NEEDED
Purchase hose, regulator and shutoff
valve that has a minimum rating of 150
PSI and exceeds the maximum working
pressure of the compressor.
4
Cord
3 wire 14 Gauge
3 wire 14 Gauge
3 wire 12 Gauge
3 wire 12 Gauge
OIL DRAIN EXTENSION
Some models include an oil drain
extension and cap (found with the owner's
manual). Install the oil drain extension and
cap before adding oil to the pump. To
avoid oil leaks, it is highly recommended
to apply Teflon
®
tape or paste type sealant
to the threads on each end of the oil drain
extension. Screw the cap onto one end of
the extension. Remove the oil drain plug
from the base of the pump and install the
oil drain extension (See Figure 5).
Dipstick
Breather
Add Oil
Oil Drain Extension
Cap
Figure 5
LUBRICATION
OIL! Follow lubrication instructions
before operating compressor.
Ensure oil drain extension and cap has
been installed (if included) then remove
the dipstick breather (See Fig. 5) and fill
pump oil according to the chart.
Model
Approx. Oil Capacity
VS260000KB
VT470200KB
VT470000KB
See specification label on air tank for
pump model number and refer to the
chart for the proper oil capacity. Use
SAE 30 industrial grade air compressor
oil. Do not use automotive oil such
Nema Plug
125V, 15 Amp
125V, 20 Amp
125V, 20 Amp
125V, 30 Amp
Max
Full
Low
Add
THIS UNIT IS
SHIPPED WITHOUT
6 oz
11.5 oz