6.7

Fitting or removing the guard

CAUTION
Risk of injury. The accessory tool may be hot or have sharp edges.
▶ Wear protective gloves when fitting, removing or adjusting the accessory tool or other parts and when
troubleshooting.
▶ Observe the instructions for fitting the applicable guard.
6.7.1
Fitting the guard
The guard has coded locating lugs to ensure that only a guard suitable for use with the product can
be installed. The coded locating lugs of the guard fit into the guard mount on the product.
1. Fit the guard on to the arbor collar so that the two triangular marks on the guard and on the product are
in alignment.
2. Press the guard on to the drive spindle collar.
3. Press the guard release button.
4. Rotate the guard until it engages and the guard release button jumps back into its original position.
6.7.2
Adjusting the guard
▶ Press the guard release button and then rotate the guard until it engages in the desired position.
6.7.3
Removing the hood
1. Press the guard release button and turn the guard until the triangular marks on the guard and on the
product are in alignment.
2. Remove the guard.
6.8
Fitting or removing the front cover
The front cover, when used, is clipped onto the guard.
1. Position the front cover with the closed side on the standard guard and push it on until it engages.
2. To remove it, release the catch for the front cover and then lift the front cover away from the standard
guard.
6.9
Positioning the DC-EX 125/5"C dust hood (for cutting)
▶ Position the compact guard so that the on/off switch remains easily accessible and operable at all times.
6.10

Fitting and removing accessory tools

WARNING
Risk of injury. The accessory tool may work loose due to the braking effect of the motor.
▶ Wait until the accessory tool has come to a standstill before touching or gripping the accessory tool or
the clamping nut.
▶ Secure the accessory tool by tightening the clamping flange and clamping nut firmly so that no parts
work loose from the spindle due to the braking effect of the motor.
CAUTION
Risk of injury. The accessory tool may be hot.
▶ Wear protective gloves when changing the accessory tool.
CAUTION
Danger if accessory tool with integrated thread works loose! Incorrect installation of the accessory tool
can result in serious injury.
▶ Always tighten the accessory tool with integrated thread until it is hand-tight.