How To Operate Your Ceiling Fan (D1) - Fanimation Distinction myFanimation A1 Serie Manual Del Propietário

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

How to Operate Your Ceiling Fan (D1)

1. IMPORTANT: Using a full range dimmer switch
(not included) to control fan speed will damage the fan.
To reduce the risk of fire or electrical shock, do not use
a full range dimmer switch to control the fan speed.
(Figure 1)
2.
Restore electrical power to the outlet box by turning
the electricity on at the main fuse box. (Figure 2)
WARNING
Check to see that all connections are tight, including
ground, and that no bare wire is visible at the wire
connectors, except for the ground wire. Do not
operate fan until the blades are in place. Noise and
fan damage could result.
NOTE: The fan's receiver features an automatic learning
function. There are no frequency switches on the receiver
unit. The receiver will automatically scan the frequency
from the hand held control if any changes are made.
The frequency settings should only be changed in the
case of interference or if multiple ceiling fans with the
same type of control system are installed in the same
structure.
3. To make fan operational, install 3V battery (included)
in hand-held remote transmitter, with fan power off.
Then follow the remote code setting process.
(If not used for long periods of time, remove battery to
prevent damage to transmitter). Store the remote away
from excessive heat or humidly. (Figure 3)
4. Remote Control Setting and Speed (RPM)
Setting Process : (Figure 4)
1) When powering on your fan, do not press any
button(s) before pressing the "SET" button,
otherwise it will fail the learn procedure. If you press
a button before the "Set" button, please turn the
power off then on again, and start the process again.
2) After installing the unit and restoring power to
your fan, press and hold the "SET" button 1-5
seconds. You must press the "SET" button within 30
seconds of restoring power to the fan.
3) When press the "SET" button the fan will make
one musical sound and start to run to begin the control
setting process.
4) DO NOT press any button(s) after pressing the SET
button and while the fan is programming or it will fail
to program. The fan will run in both directions for a
total of approximately 5 minutes.
5) When the fan stops after approximately 5 minutes
the fan will make two musical sounds that mean the
control and speed setting process is complete. The fan
is now ready for normal use.
NOTE: If you want to change the blades: turn
All manuals and user guides at all-guides.com
18
For illustrative purposes only-not
intended to cover all types of controls
Figure 1
Figure 2
3V, CR2032
BATTERY
3V CR2032
Battery (2 pcs)
3V, CR2032
BATTERY
Figure 3
Dip Switch
Figure 4
MAIN FUSE BOX
SET