2
Product description
2.1
General description
•
Automatic identification of connected battery.
•
Automatic identification of a charged battery guarantees optimum charging results.
•
Automatic identification of a defective battery.
•
The recharging phase guarantees maximum run time of the battery.
•
Charging status display.
•
Overcharge protection.
•
Wide-range input (85 – 270 VAC / 50 – 60 Hz) allows the charger to be used world-wide.
•
Voltage monitor prevents deep discharging and battery short-circuiting.
2.1.1
LED display
Abb. 2-1
LED
Operating status
Off
Lit up green
Off
Flashing green at
0.5 Hz
Flashing green at
1 Hz
Lit up green
Lit up red
Flashing red at 2 Hz
69b_1_5 en.fm, 16.03.2015
All manuals and user guides at all-guides.com
EN
Result
No mains supply
Power supply connected
No battery contact
Battery charging, state of charge < 80%
Battery charging, state of charge > 80%
Battery is charged
Temperature in battery too high
Battery fault:
•
Short circuit
•
Faulty cell
•
Faulty electronics
P2069BA/INT 2014-06
1
Safety
Symbol
19