8 Description
The fundamentals of control technology can be taught with a mini control system integrated into this
EduTrainer
®
.
Various connection and control components are available for connection of the mini control systems:
•
Four pushbutton/latched switches at input sockets I3 through I6
•
Two analog value generators, 0 ... 10 V
•
Eight switchable outputs (relay/digital), Q1 through Q8
•
Four floating outputs, Q9 through Q12
•
Two 15-pin system interfaces
•
One RJ45 socket
Wiring of the inputs and outputs depends on the controller used and the project
(see chapter 10 Operation).
The examples in this description refer to a sample device equipped with a Siemens LOGO!
Note
Relays 6 and 7 have a common connection. Thus the upper 4 mm safety sockets of Q7 and Q8 are
connected to each other in these EduTrainers
8.1 I/O allocations for the sample control system
Inputs (X10)
L+ / M
VCC DC 12/24 V
I1 = AI3
Digital DC, max. VCC
I2 = AI4
Digital DC, max. VCC
I3
Digital DC, max. VCC
I4
Digital DC, max. VCC
I5
Digital DC, max. VCC
I6
Digital DC, max. VCC
I7 = AI1
Digital DC, max. VCC
I8 = AI2
Digital DC, max. VCC
Siemens LOGO!
®
0BA8
32
®
Analog 0 ... 10 V
Analog 0 ... 10 V
Analog 0 ... 10 V
Analog 0 ... 10 V
®
.
Outputs (X11)
1
Q1
2
1
Q2
2
1
Q3
2
1
Q4
2
X1
RJ45 LAN
®
0BA8.
© Festo Didactic 8071396