2.6.4 Danger of explosion due to aggressive substances in the
ambient air
Explosion protection is no longer guaranteed if the ambient air contains aggres-
sive substances.
• Only use the product in non-aggressive industrial atmospheres.
• If the ambient air contains aggressive substances: Get in touch with our con-
tact address to determine whether use of the product is still possible (contact
data: see back cover).
2.6.5 Danger of injury
Trip hazard due to improperly laid cables and lines
• Lay the cables and lines so that no one can trip over them.
2.6.6 Material damage
Damage due to too high mechanical loads
The product can be damaged by too high mechanical loads.
• Never twist or bend the product, or mount it when it is under tension.
• Do not use the product as a handle or step.
• Do not position any objects on the product.
Damage due to excessive high temperature
Excessive temperature reduces the product service life.
• Only use cables that are designed for temperatures of –20 °C to +90 °C, in ac-
cordance with EN 60079-14 (material protection).
Damage due to electromagnetic effect
• Do not use cathodic corrosion protection, as this may result in stray currents
that will impair the function (material protection).
3 Scope of delivery
• 1x Solenoid coil with electrical connector
• 1x Operating instructions
4 Transport and storage
4.1 Transporting the product
Hazards during transportation
To eliminate risks during transport, observe the following instructions:
• Proceed with caution and observe the information on the packaging when un-
loading and transporting the packaged product to the destination.
• Ensure that the product cannot fall down before the product is released from
the mountings (accident prevention, material protection).
• Do not stand under suspended loads (accident prevention).
• Take steps to avoid damage when lifting the product (accident prevention,
material protection).
• Heavy products and components must be carried by two people or by one
person with lifting aids (accident prevention, material protection).
• Wear appropriate protective clothing (e.g. sturdy footwear).
4.2 Storing the product
Damage due to incorrect storage
Unfavorable storage conditions can result in corrosion and material deteriora-
tion.
• Comply with the limits: see section g 13. Technical data.
• Only store the product in locations which are dry, cool, and prevent corrosion.
• Avoid direct sunlight.
• Keep the product in the original or delivery packaging until the time of instal-
lation.
• Also observe any additional storage information on the product packaging.
AVENTICS™ CO1 | R499050034-BAL-001-AI | English
Elastomer parts
Pneumatic components typically have elastomer seals that are subject to a con-
stant process of aging.
• Products that have been stored for longer than two years have a shorter ser-
vice life.
• The aging process can be accelerated by heat and light (UV rays).
If you are unsure about the status of the elastomer seals, contact AVENTICS
u
GmbH, see back cover for address.
4.3 Returning the product
Proceed as follows to return the product:
1. If the product has already been mounted: Dismount the product (see section
g 10. Dismounting).
2. Package the product in its original packaging.
If the original packaging is no longer available: Select suitable replacement
packaging in consultation with EMERSON (contact details: see back cover).
3. If the product cannot be returned immediately: Observe the storage condi-
tions (see section g 4. Transport and storage).
4. Return the product.
5 Product description
5.1 Brief description
The solenoid coil with electrical connector is electrical equipment designed for
use in explosive areas.
5.2 Identification
Name plate
1
2
3
4
5
1 Logo
3 Technical data of the product
5 Country of manufacture
7 CE mark
9 Internal factory designation
Product identification
The ordered product is clearly identified by the material number.
Check the material number (MNR) on the name plate to determine whether the
delivered product matches the number on your order confirmation or delivery
note.
5.3 Use in explosive areas
Identification of the mechanical explosion protection
The solenoid coil with electrical connector meets the requirements in the ATEX
directive 2014/34/EU of the European Union.
9
8
7
6
2 Manufacturer's address
4 ATEX identification
6 IP protection class
8 Series
13