Commissioning
Carry out a visual inspection before each start-up or re-start. Inspect the following before starting the
system:
•
Electrical connections
•
Correct seating, leak tightness and condition of piping and pipe connectors
•
Correct seating and condition of compressed air connections if pneumatic valves are used
•
Mechanical components for visible defects (cracks, loose connections etc.)
•
Fill-level of tank B101, max. 3 litres of water in entire system
Eliminate any damage discovered during inspection before commissioning.
Supply the system with 24 V DC electrical voltage with a mains power supply unit.
8
Technical data
Technical data, system
Max. operating pressure in piping
Power supply for the station
Profile plate
Station height: with one tank
with two tanks
EduKit Basic in cardboard box
outside dimensions
weight
EduKit Advanced components in Systainer V
outside dimensions
weight
Volumetric flow of the pump
Tank for clean water
Flexible piping system
Optional –
if 2-way ball valve is used:
Compressed air supply
operating pressure
© Festo Didactic 746310
50 kPa (0.5 bar)
24 V DC / 4.5 A (max. 100 W)
350 x 200 mm
670 mm
1090 mm
560 x 393 x 280 mm (H x W x D)
9,25 kg
420 x 396 x 296 mm (H x W x D)
6,75 kg
0 to 10 l/min.
Max. 3 litres
DN15 (15 mm dia.)
600 kPa (6 bar)