13 Terminal assignments, EduKit PA Advanced
Terminal
Device
I0
Flow sensor, switching output
I1
Float switch LA+
I2
Float switch LS-
I3
Capacitive proximity sensor
I4
Capacitive proximity sensor
I5
Sensor box BG15 with indicator
I6
Sensor box BG15 with indicator
Q0
Load relay
Q2
Change-over relay
Q3
Motor, pump P101
Q5
5/2W solenoid valve, spring-returned
Digital inputs and outputs, I/O terminal (1)
Terminal
Device
8
Ultrasonic sensor
7
Flow sensor
15
Pressure sensor
1
Pump
Analogue inputs and outputs, analogue terminal (2)
1: I/O terminal XD1; 2: analogue terminal XD3; 3: relay, 2 switch-over contacts KF1; 4: relay, 1 switch-over contact KF2;
5: motor controller QA1; 6: starting current limiter QA0; 7: PE terminals XE0; 8: motor terminal XD20; 9: top hat rail
Complete assignment plan
© Festo Didactic 746310
Abbreviation
Note
-BF2_GW
limit value, adjustable at sensor display
-SG11
Optional
-SG12
Optional
-BG13
Minimum level, upper tank
-BG14
Maximum level, lower tank
-BG15_cl
Optional, 2-way ball valve V107, closed
-BG15_op
Optional, 2-way ball valve V107, open
-KF2
activates-MB2 2/2-way solenoid valve V102
-K1
Relay = 0: pump is binary controlled
Relay = 1: pump is analogue controlled with 0 to 10 V
-MA1
ON/OFF, supply with motor controller
-MB7
activates rotary drive MM7 for 2A-way ball valve V107
Abbreviation
Note
-BL1
Analogue input 0-10 V DC, level height 0...220 mm (0-2,7l)
-BF2
Analogue input 0-10 V DC, flow rate 0...10 l/min
-BP3
Analogue input 0-10 V DC, pressure 0...400 mbar
-P101
Analogue output 0-10 V DC, manipulated value 0...100%