PROBLEM
Regulator will
Damaged regulator.
not shut off air
outlet.
Motor will not
Motor overload protection
run.
switch has tripped.
Tank pressure exceeds
pressure switch "cut-in"
pressure.
Extension cord is wrong
length or gauge.
Check valve stuck open.
Loose electrical connections. Check wiring connection
Possible defective motor or
starting capacitor.
Paint spray on internal motor
parts.
Pressure release valve on
pressure switch has not
unloaded head pressure.
Fuse blown, circuit breaker
tripped.
CAUSE
Replace.
Motor will start automatically
when tank pressure drops
below "cut-in" pressure of
pressure switch.
1. Check fuse box for blown
2. Check for proper fuse. You
3. Check for low voltage
4. Disconnect the other
23 - ENG
CORRECTION
Let motor cool off and
overload switch will
automatically reset.
Check for proper gauge wire
and cord length.
Remove and clean, or
replace.
inside pressure switch and
terminal box area.
Have checked by a Trained
Service Technician.
Have checked by a Trained
Service Technician. Do not
operate the compressor in
the paint spray area. See
flammable vapor warning.
Bleed the line by pushing the
lever on the pressure switch
to the "OFF" position; if the
valve does not open, replace
switch.
fuse and replace as
necessary. Reset circuit
breaker. Do not use a fuse
or circuit breaker with
higher rating than that
specified for your particular
branch circuit.
should use a time delay
fuse.
conditions and/or proper
extension cord.
electrical appliances from
circuit or operate the
compressor on its own
branch circuit.
A13570