LOGIC AR111 TRIM Installation
The LOGIC AR111 TRIM (sold separately by Iluminarc) can be used to mount the LOGIC AR111 DN M flush to a ceiling
or overhead surface. To attach the LOGIC AR111 TRIM to the LOGIC AR111 DN M, insert the LOGIC AR111 DN M into
the top opening of the LOGIC AR111 TRIM until it snaps into place. Bend the tabs inward after installing to secure.
To remove the LOGIC AR111 TRIM, bend the tabs to their original positions, push down on one of the clips, and pull the
LOGIC AR111 DN M in the opposite direction until it comes free.
Clip (x3)
Spring arm (x2)
LOGIC AR111 TRIM Mounting
Before mounting this product with the LOGIC AR111 TRIM, read the
•
The maximum ceiling thickness which the LOGIC AR111 TRIM can support is 0.866 in (22 mm).
•
The LOGIC AR111 TRIM fits into a hole with a diameter of 6.23 in (158.14 mm).
To mount the LOGIC AR111 DN M with the LOGIC AR111 TRIM attached, do the following:
1. Cut a 6.23 in (158.14 mm) hole in the ceiling or overhead surface to be used.
2. Route all cables necessary to that hole and plug into the LOGIC AR111 DN M before mounting.
3. Push and hold the spring arms on the LOGIC AR111 TRIM up and in.
4. Insert the LOGIC AR111 DN M into the hole until the edges of the hole are between the limbs of the spring arms.
5. Push the product the rest up the way up until it snaps into place. The tension of the spring arms will hold the
product flush to the ceiling or overhead surface until it is intentionally removed.
LOGIC AR111 DN M QRG Rev. 4
QUICK REFERENCE GUIDE
0.866 in
22 mm
Bend tabs (x3)
inward after
installing to
secure
Safety
6.23 in
158.14 mm
Notes.
EN
Angle as desired
on 2 axes
6