Connecting the device
Before the device can be used, the following steps must be carried out:
■ Connect the motor cable to the mains power supply
■ Insert a CR2430-3 V battery into the remote control
■ Mount the roller shutter curtain on the winding shaft
■ Set the upper and lower terminal stop point.
Connecting the device
Connection of the tubular motor to the mains power and all work on electrical
systems may only be carried out by a certified specialist electrician according to
the connection schematics contained in these instructions.
DANGER
Fatal electric shock due to coming into contact with live
components.
➢ Do not carry out any connection work on the device when it is
connected to the current supply.
➢ Make sure that the device is disconnected from the mains power
supply.
ATTENTION
Malfunctions or damage to the motor due to incorrect mains
voltage.
➢ Compare the information on the model plate with that of your local
mains power supply.
➢ Make sure that the device is only connected to a 230 V ~ 50 Hz
mains power supply.
ATTENTION
Short-circuit due to damaged cables.
➢ Make sure that the cable cannot be damaged by moving parts in
the roller shutter box.
ATTENTION
Short-circuit due to water in the motor on routing cables
incorrectly.
➢ Never route the cable vertically upwards.
➢ Always route the cable in a loop.
Routing the cable in a loop enables the water to drip off.
Connect the motor cable to the current connection provided for this
purpose.