After the engine starts, let run for 2-5 seconds and
10.
then slowly move the choke to the OFF position.
After starting, confirm the output ready indicator light
11.
is green and stays on.
FIGURE 13: Output Ready Indicator Light (HW1000i Model)
Allow the engine to run continuously and warm up
12.
before connecting any appliance.
HW1000i / HW2000i Inverter Generator Owner's Manual
All manuals and user guides at all-guides.com
Connecting Appliances
Connecting Appliances
Turn off and unplug all appliances to be plugged into
1.
the generator.
Start the generator (see "Starting Generator" on
2.
page 12).
Plug in and turn on appliances. Monitor the overload
3.
indicator light. If the overload indicator illuminates lon-
ger than 4 seconds, STOP THE ENGINE IMMEDI-
ATELY. Do not restart generator until the reason for
the overload or appliance short circuit is corrected.
FIGURE 14: Overload Indicator Light (HW1000i Model)
CAUTION
Substantial overloading that continuously lights the overload
indicator light may damage the generator. Marginal overload-
ing that temporarily lights the overload indicator light may
shorten the service life of the generator.
If appliance begins to operate abnormally, becomes slug-
gish, or stops suddenly, turn it OFF immediately. Disconnect
appliance and determine whether problem is appliance, or if
rated load capacity of generator has been exceeded.
4.
Set the efficiency mode switch to the ON position.
FIGURE 15: Efficiency Mode Switch
Stopping Generator
In an emergency:
Press the engine control switch to the STOP position.
In normal use:
1.
Turn OFF any connected appliances and unplug any
connected power cords.
2.
Allow the generator to run for 2-3 minutes.
3.
Press the engine control switch to the STOP position.
Turn the fuel valve to the OFF position.
4.
Turn the fuel cap vent to the OFF position (HW1000i
5.
model only).
www.honeywellgenerators.com
Connecting Appliances
13