Draining Fuel

1.
Turn the fuel valve to the OFF position.
OFF
FUEL
FIGURE 43: Fuel Valve — OFF position
2.
Run the engine until it stops due to lack of fuel.
3.
Place a suitable container adjacent to the generator.
Remove the fuel cap and drain all the fuel into a con-
4.
tainer.
FIGURE 44: Draining Fuel
5.
When ready to put the generator back into operation,
refill with fresh fuel (see page 22).
HW1000i / HW2000i Inverter Generator Owner's Manual
All manuals and user guides at all-guides.com
ON
OFF
p/n 101592A

Storing Generator

Storing Generator
www.honeywellgenerators.com