Adjustment screw
• Do not dismantle the tap shaft: in the event of a
• Before placing the burners back on the top place, make
• A full operational test and a test for possible leakages must
• After completing conversion, a qualified technician or
28
malfunction, change the whole tap.
sure the injector is not blocked.
be carried out after the gas conversion (using soap water
or a gas detector).
installer has to mark "V" on the right gas category to
match with the setting in rating plate. Remove the previous
setting "V" mark.
3. The correct adjustment is obtained when
the flame has a length of about 3-4 mm.
- For butane/ propane gas, the adjusting
screw must be tightly screwed in.
- Refit the control knob.
Make sure that the flame does not go
out by quickly turning from maximum
flow to minimum flow. If it does, then
remove the control knob and make
further adjustments to the gas flow,
testing it again once the adjustment has
been made.
4. Repeat this process for each one of the
gas taps.