System monitoring

General

The inverter is equipped with the Wi-Fi enabled system monitoring of the Fronius
Data Manager 2.0.
The monitoring system includes the following functions:
-
-
-
-
-
-
-
-
-
Further information about the Fronius Data Manager 2.0 can be found online in
the Fronius Data Manager 2.0 operating instructions.
Starting for the
The Fronius Solar.start App makes starting Fronius Datamanager 2.0 for the first
first time via the
time significantly easier. The Fronius Solar.start App is available from the relev-
Fronius Sol-
ant app store.
ar.start App
To start Fronius Datamanager 2.0 for the first time,
-
-
IMPORTANT! To establish a connection to Fronius Datamanager 2.0, the end
device in question (e.g., laptop, tablet) must be configured as follows:
-
1
2
own website with display of actual data and a wide variety of settings
Connection-possibility to Fronius Solar.web via WiFi or LAN
automatic sending of service messages via SMS or e-mail in case of errors
Possibility to control the inverter by setting of power limits, minimum or
maximum operational times or target operational times
Controlling the inverter via Modbus (TCP / RTU)
Allocation of control priorities
Controlling the inverter by connected meters (Fronius Smart Meter)
Controlling the inverter via a ripple control signal receiver (eg reactive power
setting or power setting)
dynamic power reduction considering the self consumption
the Fronius Datamanager 2.0 plug-in card must be installed in the inverter,
or
there must be a Fronius Datamanager Box 2.0 in the Fronius Solar Net ring.
"Obtain an IP address automatically (DHCP)" must be activated
Connect the inverters with Fronius Datamanager 2.0 or Fronius Datamanager
Box 2.0 in Fronius Solar Net
IMPORTANT! Inverters Fronius IG, Fronius IG Plus, Fronius IG Plus V, Froni-
us IG Plus A, Fronius CL, Fronius CL USA, and Fronius IG 300–500 must al-
ways be located at the beginning or end of the Fronius Solar Net ring.
For Fronius Galvo/Fronius Symo/Fronius Primo only and when linking mul-
tiple inverters in Fronius Solar Net:
set the Fronius Solar Net primary/secondary switch on the Fronius Dataman-
ager 2.0 plug-in card as required
-
One inverter with Fronius Datamanager 2.0 = primary
-
All other inverters with Fronius Datamanager 2.0 = secondary (the LEDs
on the Fronius Datamanager 2.0 plug-in cards are off)
13