Descargar Imprimir esta página

Ega Master EGATRONIK 51719 Manual De Instrucciones página 23

Pinza amperimétrica

Publicidad

Idiomas disponibles

Idiomas disponibles

AC Voltage/Voltage Frequency
Range
4.000V
40.00V
400.0V
600V
Voltage Frequency 10Hz
Caution:
- Short press "SELECT" in AC voltage/Hz scale to enter the Hz function.
- The input impedance is about 10MΩ
- Current/voltage frequency response: 45Hz ~ 400Hz, displays true RMS value
Accuracy guarantee range: 1%~100%
- AC crest factor of non-sinusoidal wave can reach 3.0 at 4000 counts while can only reach
1.8 at 6000 counts, the additional error should be added for the corresponding crest factor as
follows:
a. Add 3% when the peak factor is 1 ~ 2
b. Add 5% when the peak factor is 2 ~ 2.5
c. Add 7% when the peak factor is 2.5 ~ 3
Continuity/Diode Measurement
Function
Resistance Measurement
Range
400.0Ω
4.000kΩ
40.00kΩ
400.0kΩ
4.000MΩ
40.00MΩ
Caution:
- Measured resistance value = displayed value – resistance value of short circuited test
leads
~
60KHz
Range
400.0Ω/600.0Ω
4.000V/6.000V
Resolution
0.001KΩ
0.001MΩ
Resolution
4.000V
40.00V
400.0V
600V
~
0.01Hz
0.01kHz
Resolution
0.1Ω
0.001V
0.1Ω
0.01KΩ
0.1KΩ
0.01MΩ
Accuracy
±(1.0+5)
±(0.8+5)
±(0.5%+2)
Accuracy
≤10Ω: Consecutive beeps
≥31Ω: No beep
The median: uncertain
The open circuit voltage is
about 4V
For the silicon PN junction
diode, the voltage value is
generally about 0.5~0.8V.
Accuracy
±(1.0+2)
±(0.8+2
±(2.5%+5)
23

Publicidad

loading