Descargar Imprimir esta página

Beko QWIK-PURE 200 Instrucciones De Montaje Y De Uso página 20

Ocultar thumbs Ver también para QWIK-PURE 200:

Publicidad

Maintenance • Mantenimiento
Entretien • Manutenção
Prefilter
Main filter
Prefiltro
Filtro principal
Préfiltre
Filtre principal
Filtro prévio
Filtro principal
[gal]
200
4.9
350
9.8
20
Fig. 1
Filter mat
Esterilla filtrant
Elément filtrant
esteira de filtro
[gal]
[inch]
5.4
7.58 x 3.15 x 1.18
10.6
7.58 x 3.15 x 1.18
Fig. 2
Weight
Order Ref.
Peso
Referencia
Poids
No. de comm.
Peso
N°. de encom.
[lb]
13.2
4010713
25.4
4010714
english
Weekly wastewater test
• Fill test tube at the sampling valve.
• Compare the cloudiness with the reference
jar.
If the sample is clearer than the reference
cloudiness
• the filter is O.K. (Fig. 1)
If the sample is cloudier than the reference
cloudiness
• the filter needs to be changed! (Fig. 2)
NOTE: Never pour any foreign liquid
into the pressure relief chamber! This
can impair the filter efficiency of the
QWIK-PURE
.
®
Checking of level indicator
• Level indicator not visible:
- Filter condition of both stages is O.K.
• Red ring area visible:
- Main filter stage is clogged.
Replace filter set!
The level indicator can be equipped with an
alarm contact as an option (page 32).
This contact switches reliably in the event
of a rising fill level inside the QWIK-PURE
unit.
• Excessive inflow quantity
• Filter clogged
• Water outlet not functioning correctly
Weekly check of leaks
• Container
• Connections
Filter replacement
This is necessary when
- the water being discharged is too cloudy
(see 'Wastewater test')
- the filter is clogged (see 'Checking of level
indicator') (see page 20)
Note:
• Please observe the requirements of the
Water Resources Act and other legal regula-
tions in your country pertaining to the use and
handling of filters. As part of the operator's
duty of care you should always keep a spare
filter set.
• Only use original filter sets in order to ensure
operational reliability.
• In the event of significant differences com-
pared with the specifications of the general
technical approval, e.g. the employment of
non-original filters, the approval no longer
covers the usability of the QWIK-PURE
product. In such cases, individual approval
of the responsible local authority will be
required.
• Remove plastic bag before filter installation!
QWIK-PURE
®
®
200, 350
®

Publicidad

loading

Este manual también es adecuado para:

Qwik-pure 350