20
For switching the magnet ON
(figure 10).
Pay attention that the set-up surface for
the magnetic foot is flat, clean, rust-free
and ice-free. Remove varnish,
putty/filler layers and other materials. Pre-
vent an air gap between the magnetic foot
and the set-up surface. The air gap reduces
the magnetic holding power.
When working, always use the magnetic
base; ensure that the magnetic holding
power is sufficient.
When working non-magnetic materials,
suitable FEIN fastening devices, such as vac-
uum plates or pipe drilling devices, which
are available as accessories, must be used.
Observe the corresponding operating
instructions for these.
When working on steel materials with a
material thickness of less than 12 mm /
1
/
in, the workpiece must be reinforced
2
with an additional steel plate in order to
guarantee the magnetic holding power.
If the magnet is not positioned on a magne-
tizable plate or when the magnetic foot is
defective, the motor will not start.
Danger of burns! The surface
CAUTION
of the magnet can reach high
temperatures. Do not touch the magnet
with your bare hands.
Press the magnet switch to energize the
magnet.
Fig. 10
Switches the
magnet On/Off
=