en
24
Starting and stopping the drill motor
(figure 14).
Starting:
Switch the motor switch ON.
Stopping:
Switch the motor switch OFF.
Shutting magnet OFF:
Switch off the magnet with the magnet
power switch.
When the power supply is disconnected
while the motor is running, a protective cir-
cuit prevents automatic restarting of the
motor. Restart the motor again.
In case of improper use, the motor can
become damaged.
The magnetic core drill unit JME USA 202 M
(**) is equipped with a temperature switch.
When the motor gets too warm, the mag-
netic core drill unit switches off.
When the motor has cooled down, the mag-
netic core drill unit can be switched on
again.
To reduce the cool-down period, the motor
can be switched on by pressing and holding
the ON button. During the cool-down period,
the motor will only run while the ON button
is pressed.
Fig. 14
Switching the
drill motor on
Switching the
drill motor off