Consumables; Troubleshooting - Dustcontrol S 11000 X Traducción Del Manual De Instrucciones De Servicio Original

Ocultar thumbs Ver también para S 11000 X:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 23
Accessories S11000, S11000 X, S11000 Stainless steel
Name
Art no.
Wall bracket
5024
Floor stand
7179
Output cone
4706
Plastic bag
4714
Timer
8188
Modular ring
40407
Widening chassis
7290

Consumables

Name
Art no.
Filter
4284

Troubleshooting

Problem
Filter-cleaning does
not work.
The vacuum producer
is running but nothing
is being sucked into
the system.
The vacuum producer
is running but the
suction is weak in the
system.
The unit is blowing out
dust.
Cause
There is no compressed air.
Wrong control voltage.
The dust separator is not connected to
the vacuum producer.
The tubing system is blocked.
There is no collection device connected
to the dust separator.
The collection device is not connected
tightly to the dust separator.
The vacuum producer rotates in the
wrong direction.
Leaking hoses or a leaky tubing system.
Clogged filters.
Filter is loose or broken.
S 11000 X, Art no. 99052-A
Action
Check the piping system and associated
vacuum manufacturer.
Verify that the voltage is 24V.
Connect the tubing system between the dust
separator and the vacuum producer.
Check for blocks and remove them.
Connect a collection device (plastic sack or
container)
Make sure that the collection device is
connected tightly.
Get an electrician to change the phase.
Fix this.
Clean or replace the filter(s) (see Filter
Replacement).
Fix filters and make sure they are secure.
Replace them if necessary.
15

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

1104110400

Tabla de contenido