If the room temperature is lower than the desired value, it is advisable to set a higher order curve
and vice versa. Proceed by increasing or decreasing in steps of one and check the result in the
room.
90
85
80
70
60
50
40
30
20
20
fig. 24- Compensation curves
Adjustments from Remote Timer Control
If the boiler is connected to the Remote Timer Control (optional), the previously described
A
adjustments are managed as described in table 2.
Table 2
Heating temperature adjustment
DHW temperature adjustment
Summer/Winter Switchover
Eco/Comfort selection
Sliding Temperature
286
10
9
8
7
10
0
-10
Adjustment can be made from the Remote Timer Control menu and the
boiler control panel.
Adjustment can be made from the Remote Timer Control menu and the
boiler control panel.
Summer mode has priority over a possible Remote Timer Control heating
request.
On disabling DHW from the Remote Timer Control menu, the boiler selects
Economy mode. In this condition, the eco/comfort button on the boiler
panel is disabled.
By enabling DHW from the Remote Timer Control menu, the boiler selects
the Comfort mode (if previously enabled from the boiler panel). In this con-
dition it is possible select one of the two modes on the boiler panel.
You can make all the adjustments by using the remote timer control.
cod. 3542A220 - Rev 01 - 07/2022
ALHENA TECH K 50
OFFSET = 20
6
90
85
5
80
70
4
60
50
3
40
30
2
20
1
OFFSET = 40
90
85
80
70
60
-20
50
40
30
20
fig. 25- Example of compensation parallel
10
9
8
7
6
5
4
3
2
1
10
9
8
7
6
5
4
3
2
1
curve offset
EN